background image

23

807066 v1.00 03.21 HBP AB Install Instructions

Screen operation

Settings - Install menu

- Light Calibration

Calibrate the operating ambient light in 
order to trigger sleep mode when the light 
dims below “ambient”.

- Boiling Calibration

Follow the instructions on the screen to 
calibrate boiling.

- Power Cycle

This will turn the appliance off, then on.

Summary of Contents for Autoboil 15L

Page 1: ... 807066v1 0003 21HBPABInstallInstructions Installation instructions Zip Autoboil Hydroboil Plus Onwallboilingwater Models Hydroboil Plus 3L 5L 7 5L Autoboil 3L 5L 7 5L 15L 25L 40L Available in Australia ...

Page 2: ...2 807066v1 0003 21HBPABInstallInstructions ...

Page 3: ...ECAUTIONS 5 TECHNICAL SPECIFICATION 6 Step 1 Positioning 7 Step 2 Fastening 8 Step 3 Plumbing connection 10 Step 4 Electrical connection 11 Step 5 Assembly 13 Step 6 Commissioning 14 Step 7 Tap operation 16 Screen operation 17 Maintenance 25 Troubleshooting 26 Cleaning 27 End of life disposal 27 ...

Page 4: ...Venting Occasionally steam and or boiling water may discharge through a vent outlet or the tap Ensure the tap body is located so the tap outlet safely dispenses into the drip tray or sink bowl area and the vent is plumbed to a safe location Lifting Take care when lifting The appliance may exceed safe lifting limits If you feel this is beyond your personal capabilities please seek assistance with t...

Page 5: ...ove the cover of the appliance under any circumstances without first isolating the appliance from the power supply 9 The cold water supply to this appliance must be potable and fall within your local authority guidelines 10 The installer is responsible to supply and install all valves as required by local regulations and relevant standards 11 In hard water areas where mineral scale accumulation ma...

Page 6: ...ht when full of water See Technical specifications Sufficient space is provided to install the appliance and other components in accordance with these installation instructions Check cable and plumbing against inlet outlet positions before proceeding An easily accessible socket and double pole isolation switch correctly rated for the appliance is required For models rated below 3kW 220 240V AC 50 ...

Page 7: ...e appliance on the wall Place supplied paper template on the wall Drill holes as shown OPTION Drill holes for concealed plumbing water inlet vent outlet and electrical x x x x 1 1 1 2 100mm 3L 5L 7 5L 65mm 15L 25L 40L 150mm H 20mm W 15L 25L 40L 150mm Code Description H W D 403052 3L Autoboil 440 300 190 405052 5L Autoboil 474 330 200 1 3 ...

Page 8: ...allInstructions Step 2 Fastening 3 7 5 litre models 15 40 litre models Remove 4 screws Remove the cover Use supplied screws to mount the appliance to the wall 2 1 Autoboil twist the tap 90 degrees to allow the cover to be removed ...

Page 9: ...ble gland Terminal block Concealed access AU NZ remove filter guide for installation 1 2 15 40 litre models Strain relief bush cable gland Concealed access Filter AU NZ models Terminal block Escutcheon Tap nut Tap Autoboil twist or remove tap in order to remove cover 3L 5L 7 5L models ...

Page 10: ...length must have no more than 3 right angle bends Vent External tundish 3 2 Concealed inlet 45mm Concealed vent Concealed plumbing connection Connect cold water pipe through the rear of the appliance using a 12 7mm 1 2 BSP capillary elbow e g No 63 loose nut elbow Connect vent from the concealed rear of the appliance to a dia12 7mm pipe Vent outlet must be visible and discharge to a waste water dr...

Page 11: ... Connect a concealed power cable through the rear access opening to the terminal block live active and neutral wires via the strain relief bush Tighten the strain relief bush to secure the cable Crimp a 6 3mm QC female spade connection to the earth conductor and attach to the chassis earth male terminal An isolation switch should be installed according to AS3000 Do not turn power ON until the appl...

Page 12: ...ains input 806010 v3 1 Red 2 Blu 2 Blu 1 Red Overload Chassis Earth Tab N E L2 L1 L2 L3 L4 T1 T2 T3 T4 Contactor A1 A2 2 Red Blk L1 Brn Brn 1 1 Bl Bl Blk Grn Yel Brn Brn Blk Blu Thermostat Blk Red Red Blk 2 Brn 804815 Heating Indicator Single Phase Connection 220 240V AC 1 phase 4 3 Step 4 Electrical connection Single phase power supply 15 25L models These models have single phase connection No br...

Page 13: ...filter guide Push filter guide upwards Rotate clockwise until locked Refit cover Fix with screws top and bottom Apply thread tape to thread Turn tap until it touches the lock nut and is upright Use spanner supplied to tighten the lock nut 5 1 5 3 5 4 5 5 Refit cover 5 2 Refit tap Autoboil models ...

Page 14: ...Do not turn ON electrical power until instructed Water must be available from the tap outlet to prevent damage Water dispensed during commissioning may be boiling FILTER FLUSH FILTERED Then rotate valve to FILTERED Filter flush Australian models Rotate valve to FILTER FLUSH FILTER FLUSH FILTERED Turn ON mains water Allow 5 litres to flow from vent outlet to flush the filter Note Water should NOT f...

Page 15: ...te circle left of the Tick to Continue Boiling Calibration will commence Allow several minutes for the water to boil Calibrating Completed When completed as prompted turn on the mains water supply Select to Continue The home screen will be shown see section 2 1 The tank will fill and heat Allow 15 30 minutes for the water to reach boiling set temperature 6 4 ...

Page 16: ...osition If not push the button and simultaneous ly rotate it 90 The button should remain depressed Normal operation for filling cups and small containers Gently push the tap inwards Boiling water will flow until the tap is released Continuous operation for filling larger containers Lift the tap until it locks in a horizontal position Boiling water will flow until the tap is returned to its normal ...

Page 17: ...cording to the button action A button has no function when no icon is shown 1 Understanding icons and buttons Move to the next item highlighted Move to the previous item Confirm menu selection Move to the previous menu Perform one of 3 functions Move to the menu titled by the high lighted item Select the currently highlighted item to adjust it Confirm the value of a selected item Increment the ite...

Page 18: ...de There are 3 Home screen modes Normal mode Sleep mode Sleep override mode Current water temperature Fault Indication Current Date Time Filter days remaining Daily Energy Consumption Navigate to Main Menu Show more information Navigate to Fault Menu Sleep Mode information Show more information ...

Page 19: ...Sleep Override Mode Navigate to Fault Menu Show more information Trigger Indication Hydroboil will exit sleep mode at the time shown Hydroboil will exit sleep mode when ambient light returns to normal bright room Average Daily Energy Consumption Restart Override Timer Navigate to Fault Menu Sleep Mode Timer Indication Hydroboil will return back to sleep mode after this time Button 4 will restart t...

Page 20: ...HBPABInstallInstructions Screen operation 3 MAIN menu Main menu from Home Screen Scroll menu options Select option 4 SETTINGS Settings Date Time Set the date time Settings Temperature Set the Boiling Set Point temperature ...

Page 21: ...ons Screen operation Settings Sleep Modes menu Sleep Trigger Select the trigger that will enable Sleep Mode Sleep Action Select either reduced water temperature or switch off the appliance Timer Settings Select when Sleep Mode will be enabled ...

Page 22: ...r External filter to continue Life Usage Set the filter life default 12 months refer to the filter cartridge and the actual filter usage Disable to prevent filter change reminders Replace Filter Select this option when replacing a water filter The screen prompts to flush the new filter before resetting Press Continue to reset the filter life Filter Log Shows date of new filter installation ...

Page 23: ...gs Install menu Light Calibration Calibrate the operating ambient light in order to trigger sleep mode when the light dims below ambient Boiling Calibration Follow the instructions on the screen to calibrate boiling Power Cycle This will turn the appliance off then on ...

Page 24: ...24 807066v1 0003 21HBPABInstallInstructions Screen operation Settings Info menu Product Info Current Faults Refer to Troubleshooting to identify fault codes ...

Page 25: ...es before consumption Use only a Zip Filter in this product to ensure effective filtration and operation Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip Filter replacement instructions are included with the filter cartridge spare part kits To replace the filter cartridge To remove filter cartridge rotate the filter anti clockwise Gently pull down Have ...

Page 26: ...y PCB faulty element faulty cut out Check power supply Contact Zip authorised agent Runs out of boiling water and fails to refill Outlet tap drips Overflow from vent Excessive steam from vent Power on but no heat Overload repeatedly tripping with excessive steam Overload repeatedly tripping without excessive steam Internal adjustment Contact Zip authorised agent In the event of a fault or failure ...

Page 27: ... Stainless steel surfaces will show scratches if an abrasive cleaning product is used Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details ...

Page 28: ...t prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2021 Zip Water Aust Pty Ltd Zip Water Aust Pty Ltd ABN 46 000 578 727 67 77 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Telephone 612 9796 3100 Free Call 1800 947 827 zipwater com WMKA00099 AS 3498 Zip Water UK Trafalgar House Rash s Green Dereham Norfol...

Reviews: