INSTALLATION INSTRUCTIONS & USER MANUAL 

210005 V2.00 AUG 2017 - ZIP APIII/5-15(OB)

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

•  Switch on the electrical supply to the unit. The red neon light will glow during the heating 

cycle and will extinguish when the selected temperature is reached re-lighting again for 
the next heating cycle. 

•  During the heating cycle no water should escape to waste from either the expansion 

relief or T&P valves.

•  Allow the heater to reach the selected temperature and when the indicator light has 

extinguished, check the water temperature and re-check the water connections 
adjusting as necessary.

•  Please pass these instructions on the person responsible for the building and it’s 

management.

Precautions

•  The Zip Aquapoint III is an unvented electric water heater and only a competent person 

(electrician or plumber), familiar with unvented systems, should carry out any servicing 
and maintenance work on this unit.

•  DO NOT Remove the cover whilst the unit is connected to the electrical supply. 

 

When the neon indicator light is extinguished the unit is still connected to the 

electrical supply, only by operating the ‘double pole isolating switch’ can the unit 
be disconnected from the supply.

•  The over temperature safety cut-out reset is located inside the cover. DO NOT reset the 

over temperature cut-out until the cause of it’s operation has been correctly diagnosed 
and corrected.

•  DO NOT use the water heater if it is suspected of being frozen. Switch off the electrical 

supply if water ceases to flow and do not switch it back on until a competent person 
(electrician or plumber), has checked that it is safe to do so.

•  The heater should be visually inspected regularly. This is particularly important if the 

heater is located in a cupboard, roof space or any other concealed location. If there are 
any signs of leaks or seepage the heater should be isolated from the water supply and 
switched off from the electrical supply until a competent person (electrician or plumber), 
has investigated the cause.

•  DO NOT block or restrict the discharge from any safety valve.
•  DO NOT tamper with any safety valve.
•  If water discharges from any safety valve, switch off the electrical supply to the unit, 

isolate the water supply and contact a competent person (electrician or plumber) 
familiar with unvented systems.

•  Please note that limescale forms more readily at higher temperatures. Damage or 

failures caused by the formation of limescale  are specifically excluded under the 
terms of the warranty. To reduce limescale formation to a minimum the unit should 
always be operated at the lowest convenient temperature.

COMMISSIONING AND OPERATION

MAINTENANCE

Summary of Contents for AQUAPOINT III AP3/05

Page 1: ...0 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP AQUAPOINTIII INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER AP3 05 AP3 15...

Page 2: ...ation 14 Maintenance 15 Precautions 15 Schedule 16 De installation 16 Fault finding 17 End of life disposal 18 Warranty 19 Contact details 20 Please read these instructions carefully before commencing...

Page 3: ...nti corrosion protection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting...

Page 4: ...ic precautions See installation and operating instructions Smart value 0 Rated volume l 6 2 6 6 9 8 9 9 14 8 14 9 Weight empty full kg 6 5 13 5 8 5 18 5 9 8 24 7 Power rating W 2 000 Nominal supply vo...

Page 5: ...the appliance See Technical data page 4 The connecting cable must be adequately secured This appliance must be earthed at all times Check that the power supply is switched off prior to electrical con...

Page 6: ...rking order The appliance must be installed in a frost free room and must never be exposed to frost The appliance must be completely filled with water before the electrical supply is switched on The A...

Page 7: ...2 11 REF ITEM DESCRIPTION 1 AQ0330 Element 2 AQ0331 Gasket 3 AQ0332 Control knob lens 4 AQ0333 Thermostat 5 AQ0334 Resettable cut out 6 AQ0335 Sacrificial anode 10 15 litre 7 AQ0347 Sacrificial anode...

Page 8: ...heck that the items listed below have been supplied in the Aquapoint III pack ITEM QTY Wall Bracket 1 Fixing Screws 2 Rawl plugs 2 Expansion Relief Valve 1 2 BSP 1 AQ1 Temperature and pressure relief...

Page 9: ...essures are likely to exceed 3 5 bar fit accessory pack AQ2 and AQ3 pressure reducing valve and line strainer See diagrams 2 3 Fig 2 page 12 If required a temperature and pressure relief valve accesso...

Page 10: ...of water see Technical data page 4 The undersink unit can be placed unsupported on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear...

Page 11: ...ine the accessories required to suit your layout Position the heater and controls to allow for future maintenance All control and safety valves are marked with the direction of flow and will not funct...

Page 12: ...reducing valve COLD WATER SUPPLY TO DRAIN VIA TUNDISH Length A COLD WATER DRAW OFF Minimum length of pipe Length A 5 Litres 1 2m 4ft 0 6m 2ft 10 Litres 2 7m 9ft 1 2m 4ft 15 Litres 4 2m 14ft 1 8m 6ft S...

Page 13: ...a minimum break rating of 13 amps If the cable length is insufficient it is recommended that the entire length of cable is replaced with no joins to the original To replace the cable Prise the tempera...

Page 14: ...quired position The economy e setting will maintain the most economical stored water temperature at approx 41 C for models AP 05 OB AP3 05 or 35 C for models AP3 10 OB AP3 10 AP3 15 OB AP3 15 Lime sca...

Page 15: ...supply The over temperature safety cut out reset is located inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected DO...

Page 16: ...eck the condition of the anode electrically disconnect the wire between the anode and the vessel and check that the current between anode and vessel exceeds 0 4mA Ensure that the wire is reconnected a...

Page 17: ...e commission Thermostat failure Isolate the heating system and check the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water dis charge from tundish Pressure reduc...

Page 18: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Page 19: ...t of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its distributor This warranty does not cover damage resulting from non operat...

Page 20: ...005 V2 00 AUG 2017 ZIP APIII 5 15 OB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Reviews: