Zip Hydroboil Plus - Installation & Operating Instructions - 89956UK - January 2012 v1.04

 

Read These Warnings First

Please read all installation requirements, installation procedures and precautions before 
installing any Zip Hydroboil Plus instant boiling water heater.

Never attempt to install any Zip Hydroboil Plus instant boiling water heater without reading 
all of the applicable instructions.

In some hard water areas where mineral scale accumulation in the boiling chamber of 
the Zip Hydroboil Plus may become a problem, consideration should be given to the 
maintenance required. A suitable form of water treatment may be necessary.

All plumbing connections must be made in accordance with local regulations.

The Zip Hydroboil instant boiling water heater is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning use of the 
appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the appliance.

Young children should be prevented from having access to ensure that they are not able to 
use or play with the heater.  

If the installation site is located more than 1000 metres above sea level, the installer should 
contact a Zip authorised agent for high altitude settings.

This appliance must be earthed. If the power supply cable is damaged it must be replaced 
by a Zip authorised agent or a qualified electrician. 

Do not remove the cover of the heater under any circumstances without first isolating the 
heater from the power supply.

Do not use strong, corrosive or abrasive cleaners to clean the case of the heater.

Frost protection: If this heater is located where ambient air temperature could fall below 5ºC 
when the heater is not in use, do not turn off the appliance electrically. This safeguard does 
not offer the same protection to the connecting pipework and fittings.

This heater is intended only for indoor use and should never be installed outdoors or be 
exposed to the elements of nature.

This unit must not be positioned in an area that may be cleaned by a water jet. This unit 
must not be cleaned by a water jet.

Before installing, ensure that the following are available:

a) 

Sufficient space to position the heater so there is at least 150 mm  

 

clearance above the heater for service access, 65 mm to its left and 

20 mm to its right – the tap outlet usually should be positioned at least 

200 mm above a draining board or drip tray.

b) 

Standard local requirement power cable positioned as shown on the paper mounting 

template for connection from the rear of the heater to the terminal block within the heater, 
this will require an isolating switch fitted in the fixed wiring and attached to a secure 
surface. This switch must provide all pole disconnection and a contact separation of at least 
3mm installed in accordance with the wiring rules.  Alternatively a standard 220-240V, 13 
amp fused spur, within 1500 mm of the Hydroboil Plus Unit.

c) 

Cold water supply with a minimum working pressure of 0.7 bar and a maximum 

working pressure of 7 bar connected via an isolation valve.

d)  Outlet drainage to a sink draining board or to a drip tray.

e)  Access to drainage from a vent situated at the base of the heater.

f)  In all installation instances the walls of the heater must be vertical and the base 

Installation Requirements

Summary of Contents for 89956UK

Page 1: ...droboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Page 1 of 16 Installation and Operating Instructions Zip Hydroboil Plus Large boiling water Affix Model Number Label Here 89...

Page 2: ...Page 2 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 This page intentionally left blank...

Page 3: ...Read these warnings first 4 Installation Requirements 4 5 Installation Procedures 5 7 Step 1 Positioning 5 Step 2 Fastening 5 See page 6 Wall Mounting Template Dimensions Step 3 Connecting 6 a Plumbi...

Page 4: ...g the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall...

Page 5: ...tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm l...

Page 6: ...dversely affect the operation of the heater The heater must be installed with an isolating valve which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum...

Page 7: ...outlet Turn power ON After a short period boiling water will be available and will be maintained close to boiling point thereafter Initial heating periods are shown in the table on the left Warning t...

Page 8: ...panel until it latches in the closed position and the unlocked indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water...

Page 9: ...n have 2 ON OFF times per day If the user selects either of the energy saver modes see below ON OFF mode cannot be used The user is not able to access this part of the configuration The real time cloc...

Page 10: ...the ambient light in the room where the Hydroboil Plus is installed drops below 100lux the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be mainta...

Page 11: ...2 To increment the Minutes press CSS3 To step to the next configuration parameter press CSS1 SET DAY OF THE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CS...

Page 12: ...Light sensor is configured as on pressing CSS1 will return the user to Normal Operation Note 3 If both Sleep Mode and Low Light sensor is configured as off the user will be able to use ON OFF mode SUN...

Page 13: ...rrectly Please contact your local city council for collection centre details Problem Solving Sympton Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter blo...

Page 14: ...9 90102UK Cistern Float S Nut Kit 10 90495UK Banjo Screw Kit 11 90174UK Contactor Kit 12 90743UK Fascia Lens 13 90994UK Fascia Assy Electronic White 13 90995UK Fascia Assy Electronic Grey 14 90620UK...

Page 15: ...Page 15 of 16 Zip Hydroboil Plus Installation Operating Instructions 89956UK January 2012 v1 04 Spare Parts 7 RQQHFWRU 6 RQQHFWRU 21 IRU Contactor Only for 40L...

Page 16: ...tration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot...

Reviews: