background image

Page 2 of 8 

803828 - Zip Filter Tap - Installation & Operating Instructions - Nov 2015 v1.02

 

  Installation Instructions

Please read all Warnings, Installation Requirements and Installation Instructions before installing any 
Zip Filter Tap.

These appliances are not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliances by a person responsible for their safety.

Children should be supervised to ensure they do not play with the appliances.

The units are for indoor use only and must not be exposed to the elements of nature.

These units must not be positioned in an area that may be cleaned by a water jet. These units must not be cleaned by a 
water jet.

WARNING:

 For correct operation of this appliance it is essential to observe the manufacturer’s instructions. 

Precautions

The plumbing installation must be done in accordance with local Water Authority regulations and these Installation 
Instructions.

As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and 
relevant standards.

Correct Use of JG Quick Connect Fittings

John Guest quick connect fittings and hoses are used in Zip products.  

Note insertion and removal details for JG fittings using plastic tubing as 
seen in the adjacent diagram.

NB: 

Be sure to cut the tube squarely with a sharp knife or tube cutter. 

Shake out and remove any swarf or debris.

• 

Operating temperatures 5º C -  35º C.

• 

Water pressure 70 kPa - 700 kPa  (0.07 MPa -0.7 MPa)

It is the installers responsibility to ensure the installation complies with, AS/NZS3500.4 and local water authority 
regulations. 

Installing the Filtration Unit

The filtration unit should be mounted in a convenient position in the cupboard, to allow for ready and easy access during 
filter changes.

Usually the side of the cupboard, near the door, is most suitable.

Using the two screws provided, screw the filter head bracket to the inside of the cupboard, allowing 270 mm minimum 
clearance between the underside of the filtration head and any obstructions like shelves, etc.

After removing all the filter packaging material, write the installation date on the filter cartridge. Fit the cartridge into the 
housing. The model you have may appear slightly different to that illustrated, however, operation and function is identical.

Align the tabs of the cartridge with the filter housing and insert it into the socket. Turn the cartridge a quarter turn to the 
right until it stops and locks into position.

Check that the direction of flow on the filter head is correct.

 Warnings

 John Guest fittings

Summary of Contents for 803828

Page 1: ...Filter Tap Installation Operating Instructions Nov 2015 v1 02 Page 1 of 8 Installation and Operating Instructions Zip Heavy Duty Filter Tap Cold Water Filtration unchilled Affix Model Number Label He...

Page 2: ...John Guest quick connect fittings and hoses are used in Zip products Note insertion and removal details for JG fittings using plastic tubing as seen in the adjacent diagram NB Be sure to cut the tube...

Page 3: ...orts prior to the fitting of the white tubes Measure and cut the white tube from the Filter Tap to length so that it runs around the back of the cupboard to the outlet side of the filter housing Use a...

Page 4: ...Operating Instructions Nov 2015 v1 02 Installation Diagram 350 kPa Double Non Return DNR and pressure limiting Valve 90992 Filter Cartridge 92337 Filter head JG Elbow JG 1 4 x 3 8 NPT fittings RED Tu...

Page 5: ...ter This is normal The water will become clear after the first few litres Complete the installation and leave these instructions with client Service All service work must only be carried out by a suit...

Page 6: ...ement cartridges can be obtained through plumbing suppliers or directly from Zip Replacing a Zip Filtration cartridge is as easy as 1 2 3 1 To remove the filter shut off the service valve and Turn the...

Page 7: ...re or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts EPA Establishment 070595 CT 001 To reduce the risk associated with hazard...

Page 8: ...ralia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 Contact Details As Zip policy is one of continuous product improvement changes to specifications...