Zip 801621UK User Manual Download Page 20

Page 20 of 24 

801621UK G4 Commercial boiling (ambient), User Guide - Jan 2016 - V2.02

   LCD Screen operation - Section G 

On/Off mode menu

Individual set screen

Group set screen

A

A

Note

 Any attempt, during off mode, to dispense water, will bring the unit out 

of sleep mode. The unit will return to sleep mode after 2 hours of non use. 

Please allow sufficient time for the water to reach the set temperature after 

disabling the sleep mode. 

This screen allows you to select the 

individual days for programming. 

Only one On/Off period is allowed for 

each day. 

On/Off  mode allows the user to turn the 

unit on or off at a specific time. 

To activate On/Off mode 

• 

Press the [MENU] button for main 

menu. 

Press the [Settings] button. 

Enter your 4-digit password  and 

press [Enter].

• 

Press the [Energy Modes] button 

then [On-Off Modes Menu] button.

• 

Select ‘Individual Set’ if you wish 

to allocate a specific time for each 

day.

• 

Select ‘Group Set 1’ if you wish to 

allocate the same time to all seven 

days.

• 

Select ‘Group Set 2’ if you wish 

to allocate the same time to the 

five working days (Mon-Fri) and 

additional times for weekends 

(Sat-Sun).

Note

 

Any attempt, during off mode, to dispense water, will bring the unit out 

of energy mode. The system will revert to the energy mode setting after 30 

minutes of non use.

• 

Select ‘Group Set 1’ / ‘Group Set 

2’ then press [NEXT]. 

• 

Press button        to enable and 

set the On/Off time by scrolling 

with the up & down arrow keys.

Summary of Contents for 801621UK

Page 1: ...801621UK G4 Commercial boiling ambient User Guide Jan 2016 V2 02 Page 1 of 24 Affix model number label here 801621UK ZIP HydroTap G4 User Guide...

Page 2: ...2 Tap safety Page 3 Tap operation Pages 4 to 7 Safety sensor calibration Page 8 Tap lights Page 8 to 9 LCD screen menu Pages 10 to 22 Filter maintenance Pages 22 to 23 Home menu icons Page 24 Contact...

Page 3: ...Classic or touch the AMBIENT button Elite keep both fingers in position for a period of approximately ten seconds The safety lock indicator light will illuminate Classic only To deactivate the safety...

Page 4: ...on Classic Depress the red BOILING lever while simultaneously covering the safety lock button with a second finger These two actions need to occur within 2 seconds for the successful dispensing of bo...

Page 5: ...ispense ambient water Classic Depressing the blue AMBIENT lever allows the dispensing of AMBIENT water Pulling forward the blue AMBIENT lever allows the tap to operate in a no touch mode Water will fl...

Page 6: ...orward direction and when released will return to the OFF position When rotated in the reverse direction the tap operates in a POT FILL mode Water will flow from between 5 and 15 seconds This is user...

Page 7: ...The final temperature will be dependant on the temperature of the incoming cold water Increase flow Decrease flow Cold Hot Classic mixer Arc mixer Cube mixer Arc Cube mixer taps Moving the lever away...

Page 8: ...the installation All direct sunlight must be shaded from the HydroTap G4 during the calibration This can be achieved by closing any nearby curtains blinds etc Safety sensor calibration Tap lights Blue...

Page 9: ...ent Filter light Classic and Elite Filter light off This indicates the filter is operating within its normal specified lifespan Filter light flashing slowly The light will flash slowly when the filter...

Page 10: ...Mode System is in sleep mode Boiling water or hot water is not available Refer to section G Energy modes Change Filter External Internal filter needs to be replaced Refer to section C Installation Sys...

Page 11: ...Filter reset Boiling calibration Booster Lux sensor calibration Start Stop Internal External Calibration options Enable Disable C Service Password protected D Security Enable password Set password Cha...

Page 12: ...screen Press System Faults to check the fault information Press button for the previous menu or press HOME button to return to the home screen Press Filter Log to check the filter resets Press button...

Page 13: ...tridge is a flush line approx 600mm long and the flush line stop cock Place the free end of the flush line into the bucket or container not supplied Press MENU button for main menu Press the Install b...

Page 14: ...he MENU button for main menu Press the Install button Press the Boost button In the next screen press YES to enable the booster dispense boiling water for 30 seconds and check the insulated outlet hos...

Page 15: ...button A password is required to enter service menu D Service LCD Screen operation Section D 5 Lux sensor calibration Press the MENU button for main menu Press the Install button Press the Lux Sensor...

Page 16: ...eration Section E To change a password Press the MENU button for main menu Press the Security button Press Change Password Enter your old 4 digit password Then enter your new 4 digit password press En...

Page 17: ...utton Choose 12 HOUR mode or 24 HOUR mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press NEXT button to set time Set Date Time...

Page 18: ...aximum of 10000 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 22 Filter mainten...

Page 19: ...ttings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the Sleep Modes button then in the next screen use the up and down arrow to select sleep mode from the 7 o...

Page 20: ...at a specific time To activate On Off mode Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button then On Off Modes Men...

Page 21: ...afety lock feature Then press button to enable hot isolation To de activate press button to disable hot isolation Then press button to enable disable the safety lock To operate the tap when in hot iso...

Page 22: ...ep a towel handy to dry up any drips To change the filter Open the door of the Command CentreTM Relieve system pressure via the filter flush stop cock a quick open and close will do Use the bucket to...

Page 23: ...ching the filter o rings and filter opening as this may cause bacterial contamination of the cartridge Moisten the o rings with water align the front cartridge label to the left as shown in the insert...

Page 24: ...reen See page 19 for details Heater is in off mode When this icon is displayed no power is being supplied to the heating element See page 19 for Energy Mode options Filter use This icon displays the f...

Reviews: