Operating Procedures

Tap Operation

Boiling water

Zip Autoboil is fitted with a two-way tap for filtered instant 

boiling water.
For instant boiling water, gently pull the top of the tap 

forward.
Boiling water will flow until the tap handle is released. 
This operation gives fingertip flow control for safe filling of 

cups and mugs.
To fill larger vessels such as teapots and saucepans, rotate 

the tap 180 degrees and depress it until it locks into a 

horizontal position. 
Boiling water will flow until the tap is returned to its normal 

vertical position. This operation allows the vessel to be filled 

without holding your hand where it may be affected by steam. 

1. Turn the 

fi

 lter anti-clockwise.

NOTE: For safe operation, the filter cartridge should be 

replaced every 6-12 months, or earlier if you notice a 

persistent reduction in water pressure from the appliance 

or an unpleasant taste or odour in the water.

To Replace Filter:

•   

 Turn the filter anti-clockwise (fig.1) and pull the 

cartridge down (fig.2). Have an absorbent cloth ready as 

a small amount of water will be released as the filter is 

removed. The cartridge should release from the filter 

head. 

•   

  Replace with a new filter by gently pushing up, 

engaging the key and turning the filter clockwise until 

the filter clicks or locks into place.

•   

  Perform filter flush by following the steps 1 - 4 only on 

page 8 (Step 7 - Commissioning). 

•   

  Go to [Replace Fitler] screen to reset the 

fi

 lter usage 

counter. Follow the instructions on page 14 (3.4.3 

Replace Filter) section for details of menu operation. 

Warning!

 

Not changing filtration cartridges when 

required, may cause the water to become biologically 

unsafe. 

If the Zip Autoboil is switched off for a long period of time 

(e.g. More than a weekend), run water through the outlet for 

at least 5 minutes before consumption.

Filter Replacement

Fig.1

2. Remove 

the 

fi

 lter by 

gently pull-

ing down.

Fig.2

Summary of Contents for 303052

Page 1: ...oil 3 Litre White 303051 Zip Autoboil 3 Litre Stainless Steel 305052 Zip Autoboil 5 Litre White 305051 Zip Autoboil 5 Litre Stainless Steel 307052 Zip Autoboil 7 5 Litre White 307051 Zip Autoboil 7 5...

Page 2: ...reduced physical sensory or mental capabilities or lack of expe rience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for...

Page 3: ...eater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5...

Page 4: ...al connections Concealed connections are preferred for superior appearance Step 1 Positioning Position the heater so the tap will drain on to a draining board or drip tray Position the base of the tap...

Page 5: ...ter It is recommended that the heater be installed with a stop cock which allows it to be isolated from the mains supply for servicing Water pressure requirements Minimum 70 kPa maximum 700 kPa 3 2 Ve...

Page 6: ...o the green terminal block on the PCB Check that the earth is connected through the PCB to the chassis with an ohm meter Warning Do not connect both options It is essential that the flex and plug cabl...

Page 7: ...lter NOTE For safe operation the filter cartridge should be replaced every 6 12 months or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or od...

Page 8: ...kwards into the locked open position fig 2 and allow the tank to fill until water flows from the tap outlet 6 Once the water is available from the tap turn off the mains water and close the tap outlet...

Page 9: ...ttons Move to the next item able to be highlighted Move to the previous item able to be highlighted Confirm menu selection Move to the previous menu Perform one of 3 functions 1 Move to the menu title...

Page 10: ...Filter Indication Days remaining of filter life Shown red filter needs replacement Sleep Mode Indication Unit will enter sleep mode at the time shown Unit will enter sleep mode when it is dark All sl...

Page 11: ...Select on the home screen to navigate to the main menu Choose Settings and select Choose an option and select 2 3 Sleep Override Mode Awake time remaining Unit will return back to sleep mode after th...

Page 12: ...n to prevent excessive steam release or high energy usage see section 4 2 3 3 Settings Sleep Modes From the settings menu choose Sleep Modes and select Choose Sleep Trigger and select and to select th...

Page 13: ...imer settings for the 2 weekend days simultane ously Adjust on off timer settings for the 7 days separately Weekdays Weekends Individual Days 3 3 3 Timer Settings Individual Days Settings Choose item...

Page 14: ...u and on the home screen are based on these 2 parameters This action will reset the filter usage counter A re minder is shown to flush the new filter before doing this see page 21 Filter Replacement S...

Page 15: ...nged requiring recalibration of the boiling point Incorrect boiling calibration points may cause excessive steam vent releases or increased energy usage Boiling calibration is recommended when the tem...

Page 16: ...t 5 2 Info Current Fault From the info menu choose Current Fault 6 Service Menu Note The service menu is used by technicians only for diagnostic purposes Menu Operation 5 Info Menu Select on the home...

Page 17: ...804545 03 17 1 00 Page 17 of 24 Wall Mounting Template Dimensions ROG QOHW 9HQW WHUQDO 3OXPELQJ OHFWULFDO LULQJ QWHUQDO 3OXPELQJ 3RVLWLRQLQJ SLQ...

Page 18: ...19 90100 Grommet Cistern to Tank 20 94458 Overload 21 94459 Side release plug 22 94460 Seal transfer tube Item Kit Number Description 23 94483 Metering Tube 1 5 3 Ltr 94461 Metering Tube 5 7 5 Ltr 24...

Page 19: ...804545 03 17 1 00 Page 19 of 24 Exploded View Diagram...

Page 20: ...e turned off Blocked filter blocked meter tube blocked strainer jammed ball valve assembly Check filter flush valve position see Step 7 page 8 Check filter is inserted correctly see page 21 Check wate...

Page 21: ...on in water pressure from the appliance or an unpleasant taste or odour in the water To Replace Filter Turn the filter anti clockwise fig 1 and pull the cartridge down fig 2 Have an absorbent cloth re...

Page 22: ...not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or sponge and mild soapy water Dispose of the filter cartridge responsibly Use only Zip Filter in this product to e...

Page 23: ...804545 03 17 1 00 Page 23 of 24 NOTES...

Page 24: ...tinuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The standard...

Reviews: