Symptom

Possible Cause

Solution

Fails to dispense water.

Water isolating valve turned off.

Blocked filter, blocked meter tube, 

blocked strainer, jammed ball valve 

assy, airlock in transfer tube. 

Check water supply valve.

Contact Clage-Zip authorised agent.

Water not boiling.

No power.

Faulty PCB, faulty NTC, faulty element, 

faulty cutout.

Check power supply.

Contact Clage-Zip authorised agent.

Runs out of boiling water and fails to 

refill.

Outlet tap drips.

Overflow from vent.

Excessive steam from vent.

Power “on” but no heat.

Overload repeatedly tripping with 

excessive steam.

Overload repeatedly tripping without 

excessive steam.

Internal adjustment.

Contact Clage-Zip authorised agent.

Warning:

 

this appliance must be earthed. 

Following remedial service the earthing continuity of the heater must be 
checked by a qualified technician using an appliance tester, or continuity tester 
of accuracy Class 5 or better. Class 5 denotes an accuracy of 5% full scale 
deflection.

1. Isolate power supply.

2. Set meter to 0 ohm with leads connected together.

3. Connect one test lead to the earth pin on the three pin plug.

4. Connect the other test lead to a bare patch of metal (preferably on the edge) 
of the top of the cover, then to the front cover of the unit. 

Warning-

 the water may be boiling - show extra care.

5. Test that in every instance the electrical resistance does not exceed 1 ohm.

Earthing Continuity Verification

If required, an earth continuity test can be 
performed by testing between the earth pin on 
the products lead and a exposed piece of metal 
on the case.

Summary of Contents for 203362 Clage- Hydroboil

Page 1: ...s Clage Zip Hydroboil Electronic Instant boiling water 203362 Clage Zip Hydroboil 3 Litre White 203361 Clage Zip Hydroboil 3 Litre Stainless Steel 205362 Clage Zip Hydroboil 5 Litre White 205361 Clage...

Page 2: ...ts Contents Read these warnings first 3 Descaling 4 Installation Requirements 4 Installation Procedures 5 6 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Elect...

Page 3: ...lay with the heater If the installation site is located more than 1000 metres above sea level the installer should contact a Clage Zip authorised agent for high altitude settings This appliance must b...

Page 4: ...Unit NOTE When installed with a plug and cord the plug must be accessible c Cold water supply with a minimum working pressure of 70 kPa and a maximum working pressure of 700 kPa connected via an isola...

Page 5: ...mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Fastening Position mounting hole template on wall and drill holes where...

Page 6: ...ical connection connect a power cable through the rear access opening of the heater to the terminal block within the heater as shown For exposed electrical connection connect the flex and plug fitted...

Page 7: ...is crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made...

Page 8: ...eam Internal adjustment Contact Clage Zip authorised agent Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified techni...

Page 9: ...l until it latches in the closed position and the unlocked indicator is illuminated Warning The unit is now capable of dispensing boiling water without the safety feature Dispensing Boiling water Clag...

Page 10: ...uld be configured as follows The Electronic Hydroboil has a real time clock that operates in 24 hour mode and can have 2 ON OFF times per day If the user selects either of the energy saver modes see b...

Page 11: ...the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be maintained at 65 C As soon as the ambient light rises above 100lux the Hydroboil returns to f...

Page 12: ...parameter press CSS1 SET DAY OF THE WEEK To return to Normal Mode press CSS4 To step to the next day of the week press either CSS2 or CSS3 To step to the next configuration parameter press CSS1 SET F...

Page 13: ...ured as on pressing CSS1 will return the user to Normal Operation Note 3 If both Sleep Mode and Low Light sensor is configured as off the user will be able to use ON OFF mode SUN ON TIME 1 To return t...

Page 14: ...Hot Tank Kit 13 90579 Overload Kit 14 90732 Tap Handle Kit 15 90733 Outlet Nozzle Kit 16 90503 Strap and Key Kit 3Litre Hydroboil 16 90504 Strap and Key Kit 5L 7 5Litre Hydroboil 17 90505 Tap Nut Kit...

Page 15: ...Clage Zip Hydroboil Electronic Installation Operating Instructions 87490 June 2009 Page 15 of 16 Spare Parts 1 2 3 4 5 6 7 3 8 9 10 11 14 15 27 16 17 18 19 20 21 23 26 24 25 12 13 22 28...

Page 16: ...o specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods CLAGE GmbH Postfach 1680 D 21306 L neburg Pirolweg...

Reviews: