background image

Zip Autoboil - Installation & Operating Instructions - 81439 - May 2012 v1.02 

Page 5 of 12

d)  Outlet drainage to a sink draining board or to a drip tray.

e)  Access to drainage from a vent situated at the base of the heater.

 

If the water pressure is likely to exceed 700 kPa, a 350 kPa pressure reducing 
valve must be installed in the cold water supply line.

f)  In all installation instances the walls of the heater must be vertical and the 

base horizontal, there can be no exceptions to this rule.

Before You Begin

Locate the paper mounting-hole template packed with the heater.

Read the installation and operating instructions completely.

Decide whether to install with concealed or exposed plumbing and/or electrical 
connections. Concealed connections are preferred for superior appearance.

Step 1 – Positioning

Position the heater so the tap will drain on to a draining board or drip tray.

Position the base of the tap to be not less than 200 mm above the draining board 
(height should be increased only if essential for filling larger vessels).

Provide clearance for service access of not less than 150 mm top, 65 mm left, 20 
mm right.

Mark corner positions for the heater on the wall so as to position the paper 
mounting-hole template. 

Step 2 – Fastening

Position mounting-hole template on wall and drill  holes where shown.

Drill holes for water inlet, vent outlet and wiring if rear access is intended.

Remove cover fastening screws from heater and lift whole cover off heater.

Install plumbing and wiring and prepare pipe ends and wiring ends as shown.

Screw heater chassis to the wall using screws or bolts suited to the wall.

Screws or bolts must be capable of supporting the heater weight when filled.

Installation Procedures

COLD 
INLET

VENT 

OUTLET

INLET 

POSITION

VENT

POSITION

45mm

Elbow

15 Litre models

34.5 kg

25 Litre models

47 kg

40 Litre models

71 kg

Approximate Weight When Filled

Installation Requirements

  continued

Summary of Contents for 11052 Zip Autoboil 15 Litre White

Page 1: ...and Operating Instructions Zip Autoboil Instant boiling water 11052 Zip Autoboil 15 Litre White 11051 Zip Autoboil 15 Litre Stainless Steel 12052 Zip Autoboil 25 Litre White 12051 Zip Autoboil 25 Litr...

Page 2: ...Page 2 of 12 Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Intentionally left blank...

Page 3: ...ts 4 Installation Procedures 5 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Wall Mounting Template Dim...

Page 4: ...abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater is not in use do not turn off the applia...

Page 5: ...ng board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for ser...

Page 6: ...h to the wall as shown and plumb away to waste c Electrical For concealed electrical connection connect a power cable through the rear access opening of the heater to the terminal block within the hea...

Page 7: ...Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Page 7 of 12 Wall Mounting Template Dimensions Electrical Diagram Wall template for 15 litre 25 litre 40 litre models...

Page 8: ...al adjustment Contact Zip authorised agent Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an ap...

Page 9: ...safe filling of cups and mugs To fill larger vessels such as teapots and saucepans rotate the tap 180 degrees and depress it until it locks into a horizontal position Boiling water will flow until the...

Page 10: ...ern Float S Nut Kit 10 90495 Banjo Screw Kit 11 90110 Fascia Light Kit 12 90501 Tap Top Kit 13 90499 Fascia Lens Kit 14 90494 Metering Tube Kit 2400 w 90527 Metering Tube Kit 3600 w 90526 Metering Tub...

Page 11: ...Zip Autoboil Installation Operating Instructions 81439 May 2012 v1 02 Page 11 of 12 Spare Parts 1 20 19 18 21 17 16 14 13 15 12 11 9 8 7 6 5 4 3 2 4 4 8 8 4 10 17...

Page 12: ...2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 Contact Details As Zip policy is one of continuous p...

Reviews: