SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
Safety
This appliance is not intended for use by children under 8 years or persons
(including children under 8 years) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by
a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Refrigerant
WARNING! KEEP VENTILATION OPENINGS IN THE APPLIANCE ENCLOSURE
OR IN THE BUILT-IN STRUCTURE CLEAR OF OBSTRUCTION.
The Zip HydroTap Command Centre range uses either HIGHLY FLAMMABLE
R290, R600a or R134A refrigerant under pressure.
Check the rating plate or contact Zip before commencing work.
Maintenance of the refrigeration unit must be carried out by an
accredited service provider or qualified refrigeration technician.
Do not use mechanical devices or other means to accelerate
the defrosting process, other than those recommended by the
manufacturer.
Do not store explosive substances such as aerosol cans with a flammable
propellant in this appliance.
Qualifications
To avoid hazards, all installation procedures must be carried out by a
suitably qualified tradesperson. The power cable and power outlet must be
!
!
Compliance
In Australia electrical installation must comply with AS/NZS3000.
In Australia plumbing installation must comply with AS/NZS3500.
In Australia For residential chilled models, all refrigeration must comply
with AS/NZS 60335.2.24.
In the UK the system must be installed in accordance with water supply
byelaws, current IEEE regulations and local authority byelaws.
SECTION 2: IMPORTANT SAFETY INSTRUCTIONS
in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water droplets may discharge through a
vent outlet on the tap. If not using the font, ensure the tap body is located
so the tap outlet safely dispenses into the sink bowl.
Lifting
Take care when lifting. The Command Centre may exceed safe lifting limits.
If you feel this is beyond your personal capabilities, please seek assistance
with the lift. The weight of the Command Centre is marked on the
packaging. Do not lift the Command Centre by the front cover or any of its
connections.
Airflow
The Zip HydroTap operates within the ambient temperature range 5ºC
- 35ºC. Proper air circulation must be provided. The system will operate
satisfactorily only if the recommended air gaps are provided. The vent kit
supplied must be fitted.
Altitude
Water boils at varying temperatures at different altitudes. The HydroTap
adjusts for this during startup calibration and will recalibrate itself on a
regular basis.
Frost protection
If the HydroTap is located where the ambient air temperature could fall
below 5ºC when the system is not in use, do not turn off the Command
Centre electrically. This safeguard does not offer the same protection to
the connecting pipework and fittings.
Application
The HydroTap G5 Home series is intended to be used in household and
similar applications such as:
• Staff kitchen areas in shops, offices and other working environments;
• Farm houses and by clients in hotels, motels and other residential type
environments;
• Bed and breakfast type environments;
• Catering and similar non-retail applications.
!
UV
!