SECTION 6: Set up the ventilation
Command Centre width
!
A clearance envelope around all Command Centres must be
provided to allow ventilation for the safe and effective use of the
HydroTap system.
200mm
50mm
50mm
Use instructions supplied with individual kit parts.
!
!
Use of tools can be hazardous. Assess the risks before you start.
SECTION 6: Set up the ventilation
BC100 - BC40 models
Vent tray
The vent tray must be fitted. It provides a safe exhaust for
refrigerant gas in the unlikely event of a leak.
!
!
Vent tray dimensions WxDxH (mm):
500 x (515-555) x 40
• Cold air is drawn in through the inlet vent and gap provided by the door
buffers.
• Inlet vent is mounted over cupboard side, door or floor cut-out (see
below).
• Warm air is exhausted through vent tray.
• Observe 100mm inlet / outlet vent separation (see below).
Air outlet
100mm
4mm door buffers
(supplied)
Air inlet options