UNItivity 5000
Initial System Setup
User Manual
Copyright © 2022 Zinwave. All rights reserved.
10-10
Inactivity Timeout
This option allows the user to set a period of allowed inactivity before the user is logged out from the Hub. There
is a warning message displayed one minute before the timeout during which the user can select to stay logged in
or confirm logout. One of four time periods can be set - 15, 30, 45 or 60 minutes. Alternatively, the user can select
'Keep me logged in' but this option is only recommended where security is not a concern.
Password
You can change the password for the users your account is authorized to change by selecting the user whose
password is to be changed using the “Select user password to change” drop-down. Then, type the new password
in the two password fields and click the "Update" button.
If the current user has no rights to set a password, then no password entry fields will be displayed.
10.7 Alarms Setup
On this GUI screen, the user can define how alarm LEDs and relays are handled. Alarms can be one
of three types: Loss of Service, Service Warning and Hardware Warning.
Alarms can be customized and allow the user to select whether individual alarms from a specific
category will activate the Fault or Warning relay or will be ignored.
Clicking Restore Default sets all values to the factory default values:
•
Service Warning LED - Amber
•
Hardware Warning LED - Amber
•
Relay for Loss of Service - Fault
•
Relay for Service Warning - Warning
•
Relay for Hardware Warning
– Warning
10.8 System Maintenance
Note:
Any actions executed from this page will result in the DAS service being temporarily
interrupted.
In this section, the user can set the start time for the system maintenance window. Only one action will
occur at a time in the order (when more than one is scheduled): Software Installation, RF Calibration
then System Check. The user can also check the status of any scheduled actions.
Note:
For a software upgrade where the installation is scheduled by System Maintenance, all software
file transfers must have completed before the System Maintenance Start Time (and Day, if specified).
Otherwise, installation will be delayed until the next System Maintenance window for software
installation
.
RF Calibration
performs an end-to-end (Service Module input/output to the Remote Unit DL/UL ports)
system calibration. The user can enable a recurring calibration on a specified schedule. The user can
also perform a one-time RF Calibration.
Note:
RF Calibration values are stored in non-volatile configuration memory. The user is able to clear
all existing RF Calibration values,
if desired, by clicking the ‘Clear RF Calibration’ button at the bottom
of the screen.
System Check
performs a system-wide scan to measure the RF isolation between TX and RX
antennas on the same Remote Unit, as well as between the neighboring Remote Units. It also checks