If the above procedures do not correct the problem, contact your nearest

ZINKO

service facility. When submitting any jack or

equipment to be repaired, be sure to state the nature of the problem and indicate whether an estimate of the repair cost is needed.

PROBLEM

CAUSE

SOLUTION

Pump Reciprocates

But No Fluid Delivery

(cylinder will not extend).

Low Fluid Delivery

(cylinder extends slowly).

1. Low fluid level.

2. Pump not primed.

3. Fluid intake filter contaminated.

1. Inadequate air supply.
    a) Check air input supply.
    b) Contamination, check air side
    of pump (plugged air inlet screen)
2. Hydraulic failure.
    a) Check thew fluid inlet filter for
    contamination.
    b) Air in hydraulic system.

1. Add fluid as instructed in 

Preventive

Maintenance

 section.

2. Prime pump as instructed in 

Operation

section.
3. Remove reservoir and clean intake filter
and reinstall.
1.a) Should be 20 CFM (.57 M3/min.)
   minimum.
   b) Clean and reassemble.

2.a) Remove reservoir and clean intake
   filter and reinstall.
   b) Bleed the system as described in the

Preventive Maintenance

 section.

Pump Will Not Build To

Maximum Pressure

(no visible leakage).

1. Check the air supply.

2. Pressure regulator improperly
    adjusted (if so equipped).

1. 100 psi (7 bar) is required to obtain
maximum pressure.
2. Adjust according to instructions in

Operation

 section.

Pump Builds Pressure

But Will Not Hold
System Pressure.

1. Check hydraulic connections and
other system components for leakage,
including 3-way/4-way valve.

1. Refit or repair as needed.

Pump Will Continue To Run

Slowly Even After Desired

Pressure Is Reached.

1. Output pressure equal or higher
than relief valve setting.
2. Defective 3-way/4-way valve or
other components leaking.

1. Normal operation.

2. Repair or replace.

1. Air lubricator is set too rich (if so
equipped).

Excess Oil Spray From Muffler.

1. Set at one drop per minute.

Troubleshooting

Zinko Hydraulic Jack

Models: ZAP Series

Summary of Contents for ZAP-100 Series

Page 1: ...ss can damage hose and possibly cause personal injury 4 Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corrosive materials such as creosote impregnated objects and some paints Consult the manufacturer before painting a hose Hose deterioration due to corrosive materials can result in personal injury NEVER PAINT COUPLERS 5 In...

Page 2: ...gulator turned clockwise to allow air pressure to reach the high pressure stage Always remember that the pump regulator must be turned fully counterclockwise when the pump is used to produce 1 200 psi 83 bar or less For Pumps With Air Regulators 1 Open the air shut off valve if so equipped or connect the air quick coupler if so equipped NOTE Under certain circumstances the pump may need to be prim...

Page 3: ...ontaminated fluid from entering the pump again Refilling the Bladder If additional fluid must be added to the reservoir use only approved hydraulic fluid 215 SSU 100o F 38o C Clean the entire area around the filler plug before adding fluid to the reservoir Remove the filler plug and insert a clean funnel with filter The cylinder must be fully retracted and the air supply disconnected when adding t...

Page 4: ...922 101 22 Packing 922 101 38 Air Ventilation Plug 922 101 08 Pump Cylinder 922 101 23 Packing 922 101 39 Shipping Plug 922 101 09 Hydraulic Base 922 101 24 Air inlet Valve Seal 922 101 40 Bolt 922 101 10 Release Valve 922 101 25 Spring 922 101 41 Washer 922 101 11 Release Spring 922 101 26 O Ring 922 101 42 Cover 922 101 12 Release Valve Bolt 922 101 27 Screw 922 101 43 Oil Packing 922 101 13 Oil...

Page 5: ... Operation section 3 Remove reservoir and clean intake filter and reinstall 1 a Should be 20 CFM 57 M3 min minimum b Clean and reassemble 2 a Remove reservoir and clean intake filter and reinstall b Bleed the system as described in the Preventive Maintenance section Pump Will Not Build To Maximum Pressure no visible leakage 1 Check the air supply 2 Pressure regulator improperly adjusted if so equi...

Reviews: