Troubleshooting

P R O B L E M

C A U S E

S O L U T I O N

Air Pump

Will Not Operate.

Air Pump Acts

But Ram Will Not Rise.

1. Low air pressure.
2. Air outlet is frozen.
3. Packing defective, switching valve

defective or dirty.

4. Lack of oil.

1. Release valve is open.
2. Lack of hydraulic oil.
3. "Air-bound" in valve system.

4. Inlet/outlet valve dirty or defective,

packing defective.

1. Keep air pressure between 100-200 psi.
2. Stop using and thaw outlet.
3. Contact service center.

4. Supply oil from coupler or contact

service center.

1. Close valve clockwise.
2. Supply oil.
3. Remove spring, close valve and raise

ram.

4. Contact service center.

Ram Will Not Rise to
the Highest Position.

1. Lack of oil.
2. Release valve not securely closed.

1. Supply oil.
2. Close valve clockwise.

Ram Will Not Lower.

1. Outlet valve dirty or defective, or

packing defective.

1. Contact service center.

Ram Rises Slowly.

1. Filter is loaded, air pump packing

defective, or valve not properly
opened or closed.

1. Contact service center.

Oil Blowing From Air Pump.

1. Packing defective.

1. Contact service center.

Ram Will Not Lower.

1. Release valve defective.

1. Contact service center.

Ram Will Not

Lower Completely.

1. Deformation by overload or

eccentric load.

1. Contact service center.

If the above procedures do not correct the problem, contact your nearest

ZINKO

service facility. When submitting any jack or

equipment to be repaired, be sure to state the nature of the problem and indicate whether an estimate of the repair cost is needed.

Zinko Hydraulic Jack

Models: ZABJ-M Series

REV 092107

Summary of Contents for ZABJ-12MB

Page 1: ...NSFER LOAD TO JACK STAND 5 Lower load by turning release valve counterclockwise slightly and very slowly DO NOT TURN RELEASE VALVE MORE THAN TWICE which can cause dangerous sudden lowering NOTE Take care not to contaminate coupler with dirt or sand which may cause malfunction of jack and air pump BE SURE air hose is kept connected while centering jack under point of contact READ THIS OPERATION MAN...

Page 2: ...up Ring 29 Horizontal Pin 9 Snap Ring Push Nut 19 Ram Packing 30 Vertical Pin 10 Valve Ball 20 Ram Packing Stopper 31 Ram Spring 11 Valve Spring 21 Snap Ring 32 Ram Spring Stopper 12 Valve Plug 22 Stuffing Ring 33 Ram Assembly 14 Release Packing 23 Cylinder Packing 34 Air Pump Assembly 15 Release Assembly 24 Stopper Ring 35 Air Hose 16 Ram 25 Adj Screw Assembly 36 Air Hose Switch 17 Ram Packing Se...

Page 3: ...ir Proper Oil ISO VG 10 Never use high viscosity oil or volatile oil such as brake oil or vegetable oil which may cause malfunction We recommend annual oil replacement and inspection Please contact a ZINKO service center for service inspection 3 Storing Jack After using clean jack check sliding and rotating parts and oil as needed When storing keep ram and extension screw at lowest position and st...

Page 4: ...ervice center Ram Will Not Rise to the Highest Position 1 Lack of oil 2 Release valve not securely closed 1 Supply oil 2 Close valve clockwise Ram Will Not Lower 1 Outlet valve dirty or defective or packing defective 1 Contact service center Ram Rises Slowly 1 Filter is loaded air pump packing defective or valve not properly opened or closed 1 Contact service center Oil Blowing From Air Pump 1 Pac...

Reviews: