ZINK ZN 38694 Instruction Manual Download Page 3

Fix the light body to the bracket, adjust the angle to suit your needs. 

Testing PIR :

Turn the SENS dial clockwise to the maximum point, turn the TIME dial anti-clockwise to the minimum

point, turn the LUX dial clockwise to the Sun.

When you switch on the power, the fitting will not illuminate. After a 30 second pre-heat, when the sensor

gets the induction signal, the load will turn on. Once the load switches off, it will then turn on again after 

5-15 seconds of the sensor receiving an induction signal.

After the sensor goes off, trigger the detection field after 5-10 seconds. The load should work. 

When there is no induction signals in the sensor, the load should stop working.

Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and

sensor should not work when testing in daylight. If you cover the detection window with an opaque

object, the load should work. 

Under no induction signal condition, the load should stop working within 5-15 seconds.

NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX DIAL TO THE (SUN) POSITION, 

OTHERWISE THE SENSOR WILL NOT WORK!

2.3m - 3m 

Detection distance

4m - 8m 

S E NS

LUX

TIME

SENS: 4-8m (<20

O

C)   TIME: min 10sec±3sec,  max 7min±2min

Images for illustration purposes only – Product may differ slightly from the one shown

PIR set-up and user instructions.

Manual Override Function :

Using either of the options shown below, the light can be switched on permanently by using the manual 

override function. 

 

1.  Whilst the light is on (PIR triggered) switch the light off/on within one second and it will stay on.

2.  When the light is off i.e. PIR not triggered and powered switch the light off and on again, when the light 

comes on then switch the light on/off within one second and it will stay on.

 

To switch the unit back in to Auto Mode, switch the internal wall switch/circuit breaker once (OFF/ON) 

after 10 seconds.

  