Fix the light body to the bracket, adjust the angle to suit your needs.
Testing PIR :
Turn the SENS dial clockwise to the maximum point, turn the TIME dial anti-clockwise to the minimum
point, turn the LUX dial clockwise to the Sun.
When you switch on the power, the fitting will not illuminate. After a 30 second pre-heat, when the sensor
gets the induction signal, the load will turn on. Once the load switches off, it will then turn on again after
5-15 seconds of the sensor receiving an induction signal.
After the sensor goes off, trigger the detection field after 5-10 seconds. The load should work.
When there is no induction signals in the sensor, the load should stop working.
Turn the LUX dial anti-clockwise to the Moon. If it is adjusted to less than 3 LUX (dark), the load and
sensor should not work when testing in daylight. If you cover the detection window with an opaque
object, the load should work.
Under no induction signal condition, the load should stop working within 5-15 seconds.
NOTE: WHEN TESTING IN DAYLIGHT, PLEASE TURN THE LUX DIAL TO THE (SUN) POSITION,
OTHERWISE THE SENSOR WILL NOT WORK!
2.3m - 3m
Detection distance
4m - 8m
S E NS
LUX
TIME
SENS: 4-8m (<20
O
C) TIME: min 10sec±3sec, max 7min±2min
Images for illustration purposes only – Product may differ slightly from the one shown
PIR set-up and user instructions.
Manual Override Function :
Using either of the options shown below, the light can be switched on permanently by using the manual
override function.
1. Whilst the light is on (PIR triggered) switch the light off/on within one second and it will stay on.
2. When the light is off i.e. PIR not triggered and powered switch the light off and on again, when the light
comes on then switch the light on/off within one second and it will stay on.
To switch the unit back in to Auto Mode, switch the internal wall switch/circuit breaker once (OFF/ON)
after 10 seconds.