Zinc ZN25154 User Instructions Download Page 2

 

 

Please move the upper cover with anti-clockwise whirl as per the 

diagram on the right. 

 

Connect  the  power  and  the  load  according  to  the 

connection-wire diagram. 

 

Fix the bottom on the selected position with the inflated screw. 

 

Install back the upper cover on the sensor, then you could switch 

on the power and test it. 

 

CONNECTION-WIRE DIAGRAM:

 

(See the right figure) 

 

 

 

 

 

 

 

TEST:

 

 

  Turn  the  TIME  knob  anti-clockwise  on  the 

minimum (10s).Turn the LUX knob clockwise 

on the maximum (sun). 

  Switch  on  the  power;  the  sensor  and  its 

connected  lamp  will  have  no  signal  at  the 

beginning. After Warm-up 30sec, the sensor 

can start work .If the sensor receives the induction signal, the lamp will turn on. While there is 

no another induction signal any more, the load should stop working within 10sec

±

3sec and 

the lamp would turn off. 

 

Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, 

the sensor would not work and the lamp stop working too. If the ambient light is less than 

3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor 

should stop working within 10sec

±

3sec. 

Note: when testing in daylight, please turn LUX knob to          (SUN) position, otherwise the 

sensor lamp could not work! 

SOME PROBLEM AND SOLVED WAY: 

 

The load does not work: 

a. Please check if the connection of power source and load is correct. 

b. Please check if the load is good. 

c. Please check if the settings of working light correspond to ambient light. 

 

The sensitivity is poor: 

a. Please check if there is any hindrance in front of the detector to affect it to receive 

the signals. 

b. Please check if the ambient temperature is too high. 

c. Please check if the induction signal source is in the detection field. 

d.  Please  check  if  the  installation  height  corresponds  to  the  height  required  in  the 

instruction. 

e. Please check if the moving orientation is correct. 

 

The sensor can not shut off the load automatically: 

a. Please check if there is continual signal in the detection field. 

b. Please check if the time delay is set to the maximum position 

c. Please check if the power corresponds to the instruction. 

 

 
 
 
 
 
 
 
Helpline 

If you receive this item with parts broken or missing, please telephone: 

0333 005 0077

 

Please have ready your name, address, tel. no., product reference, where purchased 

and    parts required. An answering service is in operation outside office hours and during busy 

periods. 

We regret that we are unable to give advice on internal house wiring.

 