![ZIMO MXULFA Instruction Manual Download Page 10](http://html1.mh-extra.com/html/zimo/mxulfa/mxulfa_instruction-manual_3747134010.webp)
Page
10
Decoder-Update-and-Sound-Loading-device
MXULFA
, Test and Connection boards
MXTAPS, -V, MSTAPK, -G
Typical application:
MXTAPV
with decoder MX644D (MTC interface), connected to
MXULFA
:
Supply of the combination via connection “Power” on the MXULFA, 2-pole cable from “Schiene”
(MXULFA) to “SCHIENE” (MXTAP); on the MXULFA, a
decoder update
was just started (according to
the display), the decoder software is loaded
from a flash drive
.
MXTAPV
(not MXTAPS) with connected large-scale decoder MX696, connected to
MXULFA
; on the
MXULFA
sound loading
was just started (according to the display), the sound project is loaded
from a
flash drive
.
MXTAPV
with decoder MX645P22 (PluX22), connected to
MXULFA
:
additionally,
SUSI
cable between MXULFA and MXTAPV, for
faster sound loading via SUSI
,
MXULFA in this case is controlled
by computer
(usually software ZSP - ZIMO Sound Programmer;
USB cable to the computer; on the display information to communication between PC and MXULF).
ATTENTION
: The rail connection to the test stand must be disconnected. Never leave SUSI + rail
plugged in at the same time, this can cause damage to the decoder!
MXTAPV
with decoder MX648N18 (Next), connected to
MXULFA
:
Via operating elements and display of the MXULFA,
test operation
is active, i.e. tests motor control,
function outputs, sound of the decoder.
MXTAPV
with decoder MX648R (8-pole NEM652 interface, speaker not on interface, therefore, wires
on clamps), connected to
MXULFA
:
In this case, the
test operation
is controlled by the computer (display controller in ZSP or ZCS), there-
fore, on the display only information about communication between PC and MXULF.
Therefore, it is not possible to load more than one large-scale decoder at the same time like “small” de-
coders (see previous page - with more than one MXTAPVs). Instead, it is possible to build your own
equipment to connect large-scale decoders in parallel by SUSI cables.
ATTENTION:
To load sound into large-scale sound decoders, the SUSI interface (“SUSI” plug) on the
decoder itself has to be used; it is NOT provided on the pin connectors of the decoder and therefore