Zimmer Viewline Reference Manual Download Page 8

Contact your Zimmer Spine representative or visit us at www.zimmerspine.com

Distributed by:

Zimmer Spine
7375 Bush Lake Road
Minneapolis, MN 55439
800.655.2614

zimmerspine.com

ZS-SA0790 Rev. A  (10/13)
(851S-1001-00)
© 2013 Zimmer Spine, Inc.  

Manufactured by:

TeDan Surgical Innovations, LLC
12615 West Airport Boulevard 
Suite #200
Sugar Land, TX 77478
713.726.0886

Disclaimer:

This documentation is intended exclusively for physicians and is not intended for laypersons. 
Information on the products and procedures contained in this document is of a general nature and does not represent and does 

not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or 

therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and 

this document does not replace the need for such examination and/or advice in whole or in part.
Please refer to the package inserts for important product information, including, but not limited to, indications, contraindications, 

warnings, precautions, and adverse effects.

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.  Please see the product Instructions for Use 
for a complete listing of the indications, contraindications, warnings, precautions and adverse effects.

Printed in U.S.A.   Subject to change without notice.

ZS-SA0790_A

Summary of Contents for Viewline

Page 1: ...Viewline Tube Retraction System Reference Guide 1 Viewline Tube Retraction System Reference Guide ZS SA0790_A ...

Page 2: ... dual light ports for increased visualization and a rotating accessory arm to maximize working space In addition the Viewline System s comprehensive range of radiolucent tube options help streamline your MIS procedures The Viewline family of retractors and MIS instruments is part of a complete customizable posterior MIS solution including the PathFinder NXT Minimally Invasive Pedicle Screw System ...

Page 3: ...ube Retraction System Reference Guide Step 1 Mount the sterile Rotating Table Clamp to the bed rail The Rotating Table Clamp will directly attach to most standard operating tables Slide the Articulating Accessory Arm into Rotating Table Clamp and fully tighten at desired height and angle Fig 1 Fig 1 Retractor Arm Attachment ZS SA0790_A ...

Page 4: ...ully seated Dilator 5 in 26mm Tube shown Fig 4 Fig 3 Fig 4 Dilation Tube Retractor Insertion Step 2 Identify the appropriate entry point and incision length for the Tube Procedure General Incision Guidance Decompression 2cm off midline PLIF 3 5cm off midline TLIF PedicleScrewPlacement 4 6cm off midline Note Will vary based on patient anatomy Afterincisionhasbeenmade placeK wire if desired toidenti...

Page 5: ...lly tightened remove Dilators Fig 6 Step 7 Attach bifurcated light cable to Retractor Tube Fig 7 Fig 6 Fig 7 Dilator Removal Light Source Attachment Step 5 Loosen Accessory Arm by rotating black knob counterclockwise Attach Accessory Arm to Retractor Tube and tighten arm to the Tube Turn black knob clockwise to fully tighten arm Fig 5 Fig 5 Accessory Arm Attachment ZS SA0790_A ...

Page 6: ...m Diameter X 90mm 1 ZS 0425 Retractor Tubes 22mm Diameter X 100mm 1 ZS 0426 Retractor Tubes 22mm Diameter X 110mm 1 ZS 0427 Retractor Tubes 22mm Diameter X 120mm 1 ZS 0429 Retractor Tubes 26mm Diameter X 40mm 1 ZS 0430 Retractor Tubes 26mm Diameter X 50mm 1 ZS 0431 Retractor Tubes 26mm Diameter X 60mm 1 ZS 0432 Retractor Tubes 26mm Diameter X 70mm 1 ZS 0433 Retractor Tubes 26mm Diameter X 80mm 1 Z...

Page 7: ...ed 3 6mm rev angled cup 1 ZS 0032 Epstein Curette Bayonetted 5 2mm fwd angled cup 1 ZS 0034 Curette Bayonetted 5 2mm fwd straight cup 1 ZS 0036 Curette Bayonetted 5 2mm rev angled cup 1 ZS 0039 Epstein Curette Bayonetted 7 5mm fwd angled cup 1 ZS 0040 Curette Bayonetted 7 5mm fwd straight cup 1 ZS 0041 Curette Bayonetted 7 5mm rev angled cup 1 ZS 0038 Ring Curette Bayonetted angled 8mm 1 ZS 0050 D...

Page 8: ...e medical advice or recommendations Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case each patient must be examined and advised individually and this document does not replace the need for such examination and or advice in whole or in part Please refer to the package inserts for important product information i...

Reviews: