background image

10

10.1 Installing the product

The product can be installed from multiple sides.

1

2
3

 

Insert the centering sleeves or straight pins into the provided fits on 

the product.

 

Position the product on the mounting piece.

 

Mount the product on the mounting piece using the appropriate 

mounting screws.

1

Mounting screw

2

Straight pins

3

Centering sleeve

10.2 Installing the energy supply

NOTICE

 

You can find the information in the technical data sheet on our website.

 

Close off unused connections using pressure-resistant closures.

 

The authorized connections that are available can be found in the accessories list on our website. The 

necessary ordering information can also be found there.

 

Use compressed air in accordance with DIN ISO 8573-1 [4:4:4].

INFORMATION

The flow control valves are already mounted and closed upon delivery. This ensures that no uncontrolled 

movements take place.

The figure shows the delivered state of the product. Several connections 

are available for the energy supply.

 

If using the alternative connections, close off the connections 

pictured with corresponding grub screws.

1

1

Flow control valve

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

INSTALLATION AND OPERATING INSTRUCTIONS: 

SWM1000

DDOC00964 / a

EN / 2023-01-13

Summary of Contents for SWM1000 Series

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Angular pivot unit SWM1000 DDOC00964 THE KNOW HOW FACTORY www zimmer group com...

Page 2: ......

Page 3: ...talling the product 10 10 2 Installing the energy supply 10 10 3 Installing accessories 11 10 4 Installing the customer specific application 11 11 Commissioning 12 11 1 Adjusting the swivel angle 12 1...

Page 4: ...assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can cause serious injury or damage to health Y...

Page 5: ...the following examples require the written permission of the manufacturer Use of the product under extreme conditions such as aggressive fluids or abrasive dusts Additional drilled holes or threads Z...

Page 6: ...stood everything Observe country specific accident prevention regulations and the general safety notices The following qualifications are a prerequisite for performing various work on the product 4 1...

Page 7: ...3 5 3 1 Pneumatic cylinder 2 Joint 3 Stop screw 4 Bearing pin 5 Connecting plate 5 1 Type plate A type plate is attached to the housing of the product XXX XX XXXXXX am an The article number and the co...

Page 8: ...storage preservation Transport and storage of the product must be done only with the original packaging If the product has already been installed on the superordinate machine unit care must be taken d...

Page 9: ...he power supply against being switched on unintentionally Check the machine for any residual energy that may be present NOTICE Installation may only be carried out by qualified personnel in accordance...

Page 10: ...d connections that are available can be found in the accessories list on our website The necessary ordering information can also be found there Use compressed air in accordance with DIN ISO 8573 1 4 4...

Page 11: ...10 4 Installing the customer specific application Before installation check whether the application is suitable in terms of weight Position the application on the product with the straight pins Insta...

Page 12: ...our website for information about suitable shock absorbers 11 1 Adjusting the swivel angle The product can achieve a swivel angle of 90 The swivel angle can be readjusted by 3 per end stop via the sto...

Page 13: ...the stop screws come into contact with the respective stop surfaces Reset the shock absorber when you change the swivel angle NOTICE The damping behavior changes as the oil in the shock absorber heat...

Page 14: ...Slightly open the adjustment screw of the flow control valve Apply compressed air to the product Check the function Readjust the settings to the flow control valves and the shock absorbers as required...

Page 15: ...e adjustment screw of the flow control valve until the desired swivel time is reached Weight of attachment parts workpieces too high Adjust the values to the technical data of the product End position...

Page 16: ...Service whenever possible Dismantling and reassembling the product without authorization may result in complications as special installation equipment is required in some cases Zimmer GmbH accepts no...

Page 17: ...specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents fo...

Reviews: