background image

RS74A 

Auto Reset

 

Specifications 

Models:  RS74A and RS74M

 

 

6.1 

Pressure Range  

50 to 1500 psi (345 to 10,340 kPA) 

6.2 

Max Safety Pressure 

5000psi (34,473 kPA), all models. 

6.3 

Temperature Range 

Auto Reset 

Process temperature –45°C to 140°C 
Ambient Temperature -40°C to 60°C   

Manual Reset

 

Process temperature –45°C to 120°C 
Ambient Temperature -40°C to 40°C 

6.5

 

Certification Markings 

Class I, Division 1, Groups B, C and D; Type 4 
Ex d IIB+H2; IP54 
Zone 1 AEx d IIB+H2; IP54 
Tamb -40˚C to +60˚C; T4 
Use Supply Wires Suitable For 96˚C 

6.6 

Process Connection; NACE MR0175-2003 

2” MNPT Threaded Connection  
SA350 LF2 Class 1, Zinc Plated 
Diaphragm Inconel 718 
Retaining Ring 316 SS 
CRN: 0F10666.2 

6.7 

Input Ratings (model dependent)

 

RS74M 

Manual Reset

 

Figure 6 

Manual Reset 

Auto Reset

 

Single Pole Double Throw 
15A—125, 250 or 480 VAC 
1/4 HP—125 VAC, 1/2 HP– 250 VAC 
1/2A—125 VDC, 1/4A—250 VDC

 

Single Pole Double Throw 
15A—125, 250 or 480 VAC, 2A—600 VAC 
1/8 HP—125 VAC, 1/4 HP—250 VAC 
1/2A—125VDC, 1/4A—250 VDC

 

IMPORTANT INFORMATION -Process Temperature Testing 

Pressure Switches with the 

minimum Class 1 Div

 

1

 name plate markings 

do not meet

 CSA C22.2 No 

E60079-0:2007 which requires a maximum process temperature to be applied for explosion proof test-
ing.   
All Robinson Pressure Switches in addition to meeting the minimum Class 1 Div 1 have also been tem-
perature tested to CSA C2.2 No E60079-0:2007 and are legally allowed to have the additional markings 
of Ex d IIB+H2; IP54 Zone 1 AEx d IIB+H2; IP54 Tamb -40˚C to +60˚C; T4  

ZIMCO INSTRUMENTATION INC.

11141 15 Street NE, Calgary, AB, T3K 0Z5, Canada 

Phone: 

403-253-8320 

Email: 

[email protected] 

Website: 

www.zimco.ca

 

Summary of Contents for ROBINSON RS74A

Page 1: ... RS74A RS74M Flow Line Pressure Switch Installation Operation Manual Hazardous Location Pressure Switch 11141 15 Street NE Calgary AB T3K 0Z5 Canada Phone 403 253 8320 Email info zimco ca Website www zimco ca ...

Page 2: ...sconnected before installation calibration and maintenance 1 2 Keep all components dry and free from damage 1 3 Review applicable standards to ensure Robinson Pressure Switch is the correct switch for the application 1 4 Personnel must wear appropriate safety approved apparel for working environment 1 5 Only qualified personnel should install the Robinson Pressure Switch and accessories 1 6 A qual...

Page 3: ...the Enclosure Cover Security feature 3 2 Use a spanner wrench 1 4 pin 2 4 3 4 span to break loose the Enclosure Cover and Complete removal by hand 3 3 Connect wires to micro switch as required 3 4 Thread 1 2 MNPT electrical cord Union into the Electrical Port located on the side of the electrical enclosure housing 5 Turns 3 5 Thread Enclosure Cover back onto the Electrical Enclosure and ensure it ...

Page 4: ... of Pressure Adjusting Collar 4 2 Pressure Setting Turn Collar Clockwise to Increase Pressure Setting Turn Collar Counter Clockwise to Decrease Pressure Setting 4 3 Tighten Cap Screw Tighten Cap Screw to lock Pressure Adjusting Collar in position Adjustment Collar 5 Notes Regarding Calibration 5 1 Calibration is not required after re setting verifying trip pressure 5 2 Calibration micro switch gap...

Page 5: ...M Manual Reset Figure 6 Manual Reset Auto Reset Single Pole Double Throw 15A 125 250 or 480 VAC 1 4 HP 125 VAC 1 2 HP 250 VAC 1 2A 125 VDC 1 4A 250 VDC Single Pole Double Throw 15A 125 250 or 480 VAC 2A 600 VAC 1 8 HP 125 VAC 1 4 HP 250 VAC 1 2A 125VDC 1 4A 250 VDC IMPORTANT INFORMATION Process Temperature Testing Pressure Switches with the minimum Class 1 Div 1 name plate markings do not meet CSA...

Page 6: ...ment collar Process Connection NACE for sour service Process Connection Materials are chosen in accordance to NACE MR0175 2003 Piston Orientation Eliminate the need for pulsation dampening Field Service Microswitch replaceable no need to disassemble Pressure Switch Diaphragm Servicing Diaphragm can be replaced without disassembling Pressure Switch Pin socket available for Diaphragm Nut contact Rob...

Page 7: ...oduct and train its employees and contractors in the safe use of Robinson products in connection with the specific appli cation While the information and specifications contained in this literature are believed to be accurate they are supplied for informative purposes only and should not be considered certified or as a guarantee of satis factory results by reliance thereon Nothing contained herein...

Reviews: