Disposal
Dispose the product and battery properly at
the end of life. This is electronic waste which
should be recycled.
1. To replace the battery, detach the smoke
alarm from the mounting base by twisting
counter-clockwise.
2. Replace the battery noting the polarity. The
Smoke Alarm Sensor uses 1xCR123 battery.
3. Attach the alarm in the mounting base by
twisting clockwise until it clicks, and test
the alarm.
EN14604 : 2005/AC:2008
DoP no.: 2102-002
0333
16
Distributed by Glomex Srl
via Faentina 165/G
48124 Ravenna
Italy
Glomex assumes no responsibility for any
errors, which may appear in this manual.
Furthermore, Glomex reserves the right to alter
the hardware, software, and/or specifications
detailed herein at any time without notice, and
Glomex does not make any commitment to
update the information contained herein. All
the trademarks listed herein are owned by their
respective owners.
All rights reserved.
Glomex guarantees the Smoke Alarm Sensor
(ZB204) against manufacturing defects for
a period of 2 years from date of purchase.
Warranty can be in the form of repair or
replacement of the unit if manufacturing
defects have been found and are confirmed
by Glomex or one of its affiliates. In order to
validate warranty, either the original sales
receipt or a copy must be provided at the time
warranty is requested. Before returning any
items for warranty, please contact the Glomex
Customer Service department to receive a
RMA which should be completed and sent with
the unit to the following address:
GLOMEX S.r.l.
Via Faentina 165/G
48124 Ravenna (Italy)
complete with all the accessories supplied at
the time of purchase for shipment. The serial
number must neither be erased nor made
illegible, otherwise the warranty will be voided.
Warranty
Other certifications
• ZigBee
®
certified
• RoHS compliant according to the EU
Directive 2002/95/EC
• The ZigBoat™ Smoke Sensor is not intended
as a device to prevent and detect fire and
smoke.
CE certification
The CE mark affixed to this product confirms
its compliance with the European Directives
which apply to the product and, in particular, its
compliance with the harmonized specifications
of standard EN14604:2005/AC:2008 relating to
Construction Products Regulation 305/2011.
Other information
• Note local regulations about information to
your insurance company regarding installed
smoke alarms.
Battery replacement
CAUTION:
When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside.
CAUTION:
RISK OF EXPLOSION IF BATTERIES
ARE REPLACED BY AN INCORRECT TYPE.
DISPOSE OF THE BATTERIES IN ACCORD-
ANCE WITH INSTRUCTIONS.
Resetting
Resetting is needed it you want to connect
your Smoke Alarm Sensor to another gateway
or if you need to perform a factory reset to
eliminate abnormal behavior.
STEPS FOR RESETTING
1. Detach the sensor from the mounting base
by twisting it counterclockwise.
2. Press and hold the LED button until it flashes
continuously.
3. Release the button.
4. Resetting process is complete when the red
LED starts to blink.
Modes
SEARCHING GATEWAY MODE
Red LED light in the back of the device is
flashing every second (up to 15 minutes)
NORMAL MODE
Front LED is flashing every 45 seconds.
ALARM MODE
The simultaneous flashing of the front red LED
and sounding of intermittent audible signa
l.
When smoke is detected, the alarm will sound.
Fault finding & cleaning
• Dust particles in the smoke chamber can
be removed by vacuuming the mesh.
• High humidity condensation can be
resolved by drying the smoke alarm sensor.
• If the smoke alarm sensor does not work
when the test button is pushed, the
probable cause is a faulty battery. Replace
the battery if it is worn out.
• In case of a bad or weak signal, change
the location of the smoke alarm sensor.
Otherwise you can relocate your gateway.
• If the search for the gateway has timed out,
a short press on the LED button will restart it.
Consulta il manuale utente in italiano su:
Consultez le manuel d’utilisation en français
sur:
Siehe das deutsche Benutzerhandbuch auf:
Consulte el manual de usuario en español en:
Testing
• Always test the working order of the
Smoke Alarm Sensor after installation or
battery change.
• When pressing the sensor button, the
alarm sound should be heard.
• A network alarm test can be performed by
holding down the sensor button for at least
6.5 seconds.
Press the “button/top” of the Alarm Sensor
to acknowledge and stop the siren. For 10
minutes after the alarm has been silenced,
there will be no additional alarms to allow
ventilation of the smoke being detected.
LOW BATTERY MODE
Simultaneous audible signals and front LED
flashes every 45 seconds, means that the
battery should be replaced.
REPLACE DEVICE MODE
If there are no audible signals or the front LED
does not flash every 45 seconds, the sensor
should be replaced. The life expectancy of
smoke alarm sensors is generally 10 years,
after which point their sensors begin to lose
sensitivity.