ZigBee
TM
- Door Bell
User Manual
Door Bell
Model: Z312
Firmware:V4.0
Hardware:V1.1
Door Bell Series
Page 1: ...ZigBeeTM Door Bell User Manual Door Bell Model Z312 Firmware V4 0 Hardware V1 1 Door Bell Series...
Page 2: ...urn Off Z312 6 5 2 Join the ZigBee Network 6 5 3 Binding 6 5 4 Sleeping Mode 7 5 5 Wake up Z312 7 5 6 Enroll in the ZigBee Security System 7 5 7 HeartBeat Technique 8 5 8 Battery 8 5 9 Restore to Fact...
Page 3: ...door bell button What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multip...
Page 4: ...4 2 Product Appearance Doorbell Button Indicator Red Green Battery Cover Binding Key Auxiliary Key...
Page 5: ...on Battery life may vary based on operating conditions 4 Installation Z312 is powered using two 3V CR2450 button cell batteries Please follow the instructions for installation Step1 Remove the battery...
Page 6: ...time NOTE2 After Z312 first time joins a network or re installs the batteries it will be activated for 5 minutes 5 2 Join the ZigBee Network After Z312 is powered on it will search for an existing Zig...
Page 7: ...would consume up to 30 times power spending compared to normal operating status To prevent this unwanted power consumption we recommend that users remove the batteries to power off the device 5 5 Wake...
Page 8: ...twork in the mean time the red indicator flashes once 3 Default low voltage threshold BatteryVoltageMinThreshold 2 1V 0x15 BatteryVoltageThreshold1 2 2V 0x16 BatteryVoltageThreshold2 2 3V 0x17 Battery...
Page 9: ...table Min Interval Unit second Max Interval Unit second Reportable Change Change rate Reportable Change Change rate Reportable Change 1 65534 1 65534 0 To report per Minimum interval To report per Ma...
Page 10: ...c 0x0000 Identify 0x0003 Identify 0x0003 IAS ACE 0x0501 Commissioning 0x0015 IAS WD 0x0502 IAS Zone 0x0500 power configure 0x0001 Diagnostics Information 0x0B05 Poll Control 0x0020 This lists the attr...
Page 11: ...0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnab Boolean 0x00 0x01 Read write 0x01 M 7 Netvox App Control Interface 1 After joining in...
Page 12: ...n configurate other selection as shown below 3 In the basic information interface will show status of Z312 which is currently registered to CIE security control center including default Heart Beat car...
Page 13: ...lick EP1 into the basic information interface by clicking on the bottom of the Basic Information Settings About Device interface to switch interfaces to check detail information of the device As shown...
Page 14: ...ures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the devic...