background image

6

3

Configure Network

LED indicator

The LED status gives the following information of the occupancy 
sensor:

LED Status

What it means

No light

Device has joined a ZigBee network.

Continuous and slow
flashing

Device has not joined a ZigBee network.

Flashing once

Presence detected

When you press the reset button once

Flashing once

Device has joined a ZigBee network.

Flashing three times

Device has not joined a ZigBee network.

3.1 Before starting, you will need:

• A ZigBee Gateway.

3.2 Adding to the gateway's network

Follow the steps below to join the occupancy sensor to the gateway's 
network:
1. Power on the occupancy sensor, the LED indicator will start 
continuous and slow flashing, which meas it is ready to join the 
network. If not, please reset it.
2. Set your gateway to permit joining.
3. The occupancy sensor will join the gateway's network automatically 
and the LED indicator will go out when successfully joined.

Summary of Contents for OPS305

Page 1: ...OPS305 Occupancy Sensor Quick Start Guide...

Page 2: ...all the safety notices below before using the Occupancy Sensor Avoid high humidity or extreme temperatures Avoid long exposure to direct sunlight or strong ultraviolet light Do not drop or expose the...

Page 3: ...y 2 4GHz Range outdoor indoor 100m 30m Open area Physical Specifications Operating Voltage Micro USB Detector 10 525GHz Doppler Radar Detection Range Maximum radius 3m Angle 100 10 Hanging height Maxi...

Page 4: ...ursing homes to monitor and link with other devices to make your home smarter This guide will provide you with an overview of the product and help you get through the initial setup to installation Zig...

Page 5: ...ur device LED indicator Micro USB Reset Button Reset Press and hold the reset button for 10 seconds until the LED light flashes three times at third second and it will flash three times in the tenth s...

Page 6: ...network Flashing three times Device has not joined a ZigBee network 3 1 Before starting you will need A ZigBee Gateway 3 2 Adding to the gateway s network Follow the steps below to join the occupancy...

Page 7: ...it to an auxiliary device Always use a properly rated voltage sensing device to con rm power is off Replace all devices doors and covers before applying power to the equipment 1 The installation locat...

Page 8: ...8 2 You need to pay attention to the distance and range of the occupancy sensor when installing Within the sensing range avoid facing another occupancy sensor or radar equipment Ceiling m m m...

Page 9: ...Screw the mounting bracket onto the ceiling according to marked location Install wall plugs if necessary 5 Locate the hooks of the mounting bracket and line up the hooks with the mounting holes on occ...

Reviews: