background image

ZAIoT-VTC01

5

3. Product Specification

Hardware Specification

Frequency response

Z-axis: 10kHz (1dB point)
XY-axis: 6kHz (3dB point)

Sampling frequency

Z-axis: configurable by class: 25600 12800 6400 3200
XY-axis: 26667Hz

Frequency resolution

1Hz

Measuring range

±

33g

Working temperature

-30~85

Ingress level

IP66

Mounting

Magnetic, adhesive, M5 stud

Size

50*50*87mm

Weight

~400g (With battery)

Battery capacity

9600mAh (Replaceable)

Battery life

~3 years (default setting)

Wireless Specification

Wireless Protocol

ZETA H

Frequency band

Sub-GHz, adjustable according to local regulations

Gateway coverage

~1km

Antenna type

PCB Antenna

Functional Specification

Data collection and
return

Tri-axis vib temperature data acquisition and
return, supporting synchronous acquisition between
different nodes, to meet the application of synchronous
monitoring requirements

Vibration index report

vibration velocity rms, vibration acceleration rms

Summary of Contents for ZETA ZAIoT-VTC01

Page 1: ...ZAIoT VTC01 1 ZETA Edge AI Vibration Sensor ZAIoT VTC01...

Page 2: ...ting Instructions 8 5 1 Platform login 8 5 2 Device configuration 8 5 3 Check Status 11 6 Sensor functions 12 6 1 Equipment vibration data acquisition 12 6 2 Vibration index report 13 6 3 Power button...

Page 3: ...ginal waveform and feature edge calculation to meet the needs of multiple use scenarios The product complies with IEC 60079 intrinsically safe explosion proof standard the explosion proof mark is Ex i...

Page 4: ...ZAIoT VTC01 4 2 Appearance and size Unit mm ZAIoT VTC01 Sensor Appearance...

Page 5: ...t 400g With battery Battery capacity 9600mAh Replaceable Battery life 3 years default setting Wireless Specification Wireless Protocol ZETA H Frequency band Sub GHz adjustable according to local regul...

Page 6: ...installation The sensor supports three types of mounting magnet adhesive and M5 bolt with the threaded connection mounting being preferred If the equipment does not have the conditions for drilling a...

Page 7: ...ZAIoT VTC01 7 when shipped Check the status of the terminal on the platform to see if it is online...

Page 8: ...orm platform address https platforms zifisense com network login 5 2 Device configuration After logging in go to the Network Device ZETA MS page and click the Add button to add a new device And add th...

Page 9: ...T VTC01 9 Select from the left menu Network Device ZETA MS Add The red asterisk is a required item after filling in press OK to add the device Check the device apply Device Control Settings as shown b...

Page 10: ...chinery Acquisition of raw vibration data according to the configuration period and wirelessly backhauled through ZETA H protocol The sampling frequency and the number of spectral lines can be configu...

Page 11: ...ce in the list When the device is powered on the online status will change from offline to online and the startup time registration time and heartbeat time are updated If the data is underlined you ca...

Page 12: ...parameter query Version number query 6 Sensor functions 6 1 Equipment vibration data acquisition Acquisition of equipment triaxial vibration data Remote configuration of the reporting period Remote c...

Page 13: ...6 4 Battery replacement When the platform reports a low battery alarm please replace the battery promptly Replacement procedure Unscrew the four screws securing the terminal housing and open the housi...

Page 14: ...ZAIoT VTC01 14 terminal is successfully connected If unsuccessful operate the button to restart once...

Page 15: ...on restart which is the fastest means Check the power level reported on the last platform to see if there is a possibility of low battery Battery power drops badly Collection cycles are too frequent a...

Page 16: ...atic charging hazard clean only with a damp cloth 2 Only ER26500 lithium thionyl chloride battery produced by EVE Energy Co Ltd is allowed to be used as the power supply Do not charge the battery Do n...

Page 17: ...n part FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part...

Page 18: ...ZAIoT VTC01 18...