STW81V
12380-0710-00
Page
8 / 8
www.ziehl.de
Installation altitude
< 2000 m a.s.l.
Resistance to climatic conditions
585% relative humidity, non-condensing
Permissible wiring temperature
-5 °C …+70 °C
Vibration resistance EN 60068-2-6
2 … 13.2 Hz ±1 mm 13.2 ... 100 Hz 1 g
2…25 Hz ±1.6 mm
25 ... 150 Hz 5 g
Casing
Type V8, transducer mounting
Installation depth
58 mm
Width
8 TE
Dimensions (W x H x D)
140 x 90 x 58 mm
Cable connection one wire
1 x 0.34 - 2.5 mm² / AWG 22 - 12
Fine wire with wire end
1 x 0.34 - 2.5 mm² / AWG 22 - 12
Tightening length / torque
8 mm / 0.5 Nm
Degree of protection Casing / terminals
IP 30 / IP20
Fastening
Snap-on mounting on 35 mm mounting rail according to
EN 60 715 or screw fixing M 4
(additional clamp is not included)
Weight
approx. 300 kg.
Subject to technical changes
2 Type V8
Dimensions in mm
1.
Upper part / cover
2.
Bottom part / base
3.
Snap / bar for snap mounting
4.
Sealing latch
5.
Front panel insert / front panel
6.
Position downward
7.
Snap on wall mount with screws. Screw hole Ø 4,2 mm / for fixing
to the wall with screws, Ø 4,2 mm.
14 Entsorgung
Die Entsorgung muss sachgerecht und umweltschonend nach den gesetzlichen Bestimmungen
erfolgen.
ZIEHL ist bei der Stiftung EAR (Elektro Altgeräte Register) unter der
WEEE-Nr.: DE 49 698 543 registriert.