3.3 Transport

The device is packed ex factory to suit the transport method previously agreed.

Always use the original packaging materials when transporting the device.

Avoid shocks and impacts to the device during the transport.

During manual handling the human lifting and carrying restrictions must be observed 
and adhered to.

3.4 Storage

The device must be stored in its original packaging in a dry and weather-proof room.

Avoid exposure to extreme heat and cold.

Avoid over-long storage periods (we recommend a maximum of one year).

3.5 Disposal / recycling

Disposal must be carried out professionally and in an environmentally friendly way in 
accordance with the respective national legal stipulations.

"

Separate the materials by type and in an environmentally friendly way.

"

If necessary, commission a specialist company with the waste disposal.

4 Installation

4.1 General notes

Attention!

Mounting, electrical connection, and start-up operation may only be carried out by an 
electrical specialist in accordance with electrotechnical regulations (e.g. EN 50110, 
EN 60204, IEC 364)!

The 5 electrical safety rules must be observed!

Cover neighbouring electrical equipment during installation work.

Before installation remove the device from the packing and check for any possible 
shipping damage! Start-up is not allowed in the case of transport damage!

At a weight greater than 25 kg for men / 10 kg for women, the device should be lifted 
out by two persons (according to REFA). The values may differ from country to 
country.

Wear safety shoes and gloves for handling!

Assemble the device on a clean and stable base. Do not distort during assembly! Use 
the appropriate mounting devices for proper installation of the unit!

Do not mount equipment on vibrating base!

Do not allow drilling chips, screws and other foreign bodies to reach the device 
interior!

The device should be installed in a location where it will not be disturbed, but at the 
same time can be easily accessed!

Operating Instructions 

RAE-2/4/7/9G

Installation

L-BAL-E283-GB 1928 Index 002

Part.-No. 

6/11

Summary of Contents for RAE-2G

Page 1: ...rols for voltage controllable 1 motors Connection for 5 level thermostat for automatic speed control Operating Instructions Keep for reference L BAL E283 GB 1928 Index 002 Part No english D GB DK E F...

Page 2: ...view 5 3 1 Function 5 3 2 Maintenance 5 3 3 Transport 6 3 4 Storage 6 3 5 Disposal recycling 6 4 Installation 6 4 1 General notes 6 4 2 Minimum space requirement 7 4 3 Mains connection 7 4 4 Motor con...

Page 3: ...e developments construction methods and technical data given are subject to alteration We do not accept any liability for possible errors or omissions in the information contained in data illustration...

Page 4: ...ng of the motor fan the appropriate instructions in the drive documentation must be observed Attention Even after switching off dangerous temperatures can still occur in and on the device Attention Au...

Page 5: ...nsformer control unit for speed control of voltage controlled 1 fans In conjunction with a 5 level thermostat the fan speed is automatically adjusted to one of 5 levels For operation with no minimum a...

Page 6: ...tart up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations e g EN 50110 EN 60204 IEC 364 The 5 electrical safety rules must be observed Cover...

Page 7: ...rance on all sides of at least 50 mm has to be maintained to the housing walls switch cabinet doors wiring ducts etc The same clearance applies to the installation of several devices next to each othe...

Page 8: ...do not have the required motor protection It is recommended that every fan is equipped with a separate motor protection unit e g type S ET10 5 Enclosure 5 1 Technical data Line voltage 1 230 V 15 10...

Page 9: ...230 V AC max 0 5 A 5 Do not exceed the rated current of the internal fuse SR146K03 06 09 2017 RAE 9G N L1 PE Netz Line 1 230 V 50 60 Hz L1 N M 1 U1 U2 PE 1 Motor ohne Thermostatschalter without therm...

Page 10: ...5 3 Dimensions mm RAE 2 4 7G RAE 9G Operating Instructions RAE 2 4 7 9G Enclosure L BAL E283 GB 1928 Index 002 Part No 10 11...

Page 11: ...6 504 info ziehl abegg de http www ziehl abegg de 5 5 Service information If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for con...

Reviews: