Procedure for connecting the adapter

1. Plug the USB cable into the adapter and connect to the computer.
2. If necessary, secure the cable ties at the recess in the housing using cable ties.
3. To  update  the  I/O  printed  circuit  board,  connect  the  additional  connection  cable 

article no. 00166181 to the adapter and connect to the ECblue.

Connect the black cable to the GND terminal.

Connect the red cable to the 24 V terminal.

After completing the update or programming, remove the cables and disconnect the 
adapter. Fit the cover on the slot or replace the AM-STICK-WB if installed.
Re

t the cover of the controller housing using the speci

ed torque, see ECblue assembly 

instructions.

Operating Instructions 

IF-ECblue

Inserting and connecting the service adapter

L-BAL-E327-GB 2023/19 Index 001

Part.-No. 

8/11

Summary of Contents for IF-ECblue

Page 1: ...IF ECblue Service adapter for ECblue fans Operating Instructions L BAL E327 GB 2023 19 Index 001 Part No english...

Page 2: ...5 3 4 Storage 5 3 5 Disposal Recycling 6 4 Inserting and connecting the service adapter 6 4 1 ECblue BASIC MODBUS and ECblue BASIC of motor size B 090 D 116 G 152 7 4 2 ECblue motor size O 072 500 W...

Page 3: ...r their job 2 Safety instructions Information Mounting electrical connection and start up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations...

Page 4: ...h article number 380111 the connection cables for updating the IO printed circuit board are included in addition to article number 380112 IF ECblue Part No 380111 and 380112 1 Service adapter IF ECblu...

Page 5: ...erload 4 Main board LED Green light Voltage supply for main board active 5 I O BOARD LED Green light Voltage supply for I O board active 3 4 Storage The device must be stored in its original packaging...

Page 6: ...ted Turn o the supply voltage and secure against switching back on Before opening the device wait at least 3 minutes Check the safe isolation from supply with a two pole voltage detector Attention ele...

Page 7: ...Remove the cover from the ECblue controller housing Remove the cover from the slot for the AM STICK WB If an AM STICK WB is inserted remove it Insert the adapter in the correct position Operating Inst...

Page 8: ...dapter and connect to the ECblue Connect the black cable to the GND terminal Connect the red cable to the 24 V terminal After completing the update or programming remove the cables and disconnect the...

Page 9: ...the cable ties at the recess in the housing using cable ties 3 To update the I O printed circuit board connect the additional connection cable article no 00166180 to the adapter and attach it to the...

Page 10: ...g the IO printed circuit board Supply voltage USB 4 75 5 25 V UL 5Vdc max 0 5A Supply mainboard service interface Output voltage 3 0 3 3 V Output current 0 160 mA UL 3 3 Vdc 0 16 A Galvanically isolat...

Page 11: ...ziehl abegg de http www ziehl abegg com 6 3 Service note If you have any technical questions while commissioning or regarding malfunctions please contact our technical support for control systems vent...

Reviews: