7 Enclosure
7.1 Technical data
Line voltage*
(
rating plate)
1 ~ 230 V, 50/60 Hz
1 ~ 120 V, 50/60 Hz
Power consumption (P1)
Version with one speed: max 18 W
Version with three speeds: max. 34 W
Power output (P2)
Version with one speed: max 9 W
Version with three speeds: max. 20 W
Speed step 3 / 2 / 1
see rating plate
Maximal line fuse
4 A
Max. load limit integral of cut-in
current approx.
0.118 A
2
s
Permissible minimal and maxi-
mal ambient temperature for op-
eration
-30...+50
°
C
Permissible temperature range
for storage and transport
-40...+80
°
C
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for
the standard voltage 230 / 400 V
according to IEC 60038
Interference emission according to EN 55014-1 (domestic household
applications)
Interference immunity according to EN 61000-4-4 (industrial applications)
Harmonics current
In accordance with EN 61000-3-2
Please ask manufacturer for the individual harmonic oscillation levels of
the current as a percentage of the fundamental oscillation of the rated
current.
Ball bearings grease service-life
(F
10h
)
The device is designed with a life time for the bearings and a bearings
service-life of at least 40.000 h when S operated at full power in the
maximum permissible ambient-temperature environment.
Connection cable
Version with one speed: H03VV-F 2 x 0.5 mm
2
Version with three speeds: H03VV-F 3 x 0.5 mm
2
Thermal class
THCL130
Safety class
II
Protection class of motor ac-
cording to EN 60529
IP55
Weight
see rating plate
For motors with corresponding quality mark, marking depend-
ent on temperature class T4 or T5 (see rating plate)
ATEX approval
II 3G nA IIA T4
II 3G nA IIA T5
Assembly instructions
ECQ
Enclosure
L-BAL-F071-GB 1642 Index 001
Part.-No. 00703698-GB