7 Enclosure
7.1 Technical data
Line voltage*
(DC supply not UL and VDE ap-
proved!)
Voltage spezi
fi
cations see rating
plate
DC voltage range
1 ~ 200...277 V, 50/60 Hz
280...400 V (+/- 2 %)
1 ~ 100...130 V, 50/60 Hz
140...400 V (+/- 2 %)
DC 110 V
110...400 V (+/- 2 %)
Maximal line fuse**
16 A
Max. load limit integral of cut-in
current approx.
2.0 A
2
s
Switching Freq.
16 kHz
Voltage supply for external devi-
ces
+10 V (-2 %), I
max
50 mA (short-circuit-proof)
Analogue input
“
E1
”
Input resistance: R
i
> 100 k
Ω
Speci
fi
cation speed setting signal PWM
Voltage: 15...28 VDC
Switching Frequency: 1...10 kHz
On-off ratio: 0...100 %
Digital input
“
D1
”
Input resistance: R
i
approx. 2 k
Ω
Voltage range high level: 7.1...19 V DC
Voltage range low level: 0....2.7 V DC
Open-Collector output
“
A1
”
I
max
: 20 mA
U
CE max
: 30 V DC
Contact rating of the internal relay
“
K1
”
AC 250 V 2 A
Permissible minimal and maximal
ambient temperature for operation
-35...60
°
C (
rating plate) ***
Please see the technical documentation of the product for the minimum
and maximum ambient temperature valid for the respective fan ; these
may deviate from the speci
fi
ed permissible ambient temperatures.
To avoid condensation the drive must be continuously energized due
to the application of heat, with interruptions such that cooling to the
point of condensation does not occur.
Max. permissible installation
height
height 1000 m amsl without derating
Permissible rel. humidity
The motor is released for a relative humidity of 100 % at continental
climate without other ambient in
fl
uences. Other ambient conditions on
request.
Permissible temperature range for
storage and transport
-40...+80
°
C
Electromagnetic compatibility for
the standard voltage 230 / 400 V
according to IEC 60038
Interference emission EN 61000-6-3 (domestic household applica-
tions)
Interference immunity EN 61000-6-2 (industrial applications)