Cleaning of Freezing Unit

Depending on the water quality a layer of solids may form after a while 
in the freezing cylinder or on the auger.

Vibrations or noises in the freezing cylinder, e.g. "rumbling" and production of powdery ice may be a symptom  
of such deposits. 
As the freezing unit has to be completely clean inside in order to ensure proper freezing and an even upward 
conveying of the ice on the auger, this layer has to be removed.

Remove tenacious deposits on the auger with steel wool.

However, these deposits often are of calcareous nature, which can be removed with an antilime
agent, e.g. ZIEGRA cleaning agent:

o

Switch the ice machine off, close the water tap and wait 1-2 hours
until the ice in the freezing unit has totally melted.

o

Detach the water-inlet pipe at the bottom of the freezing unit, drain the water from the water chamber 
and the freezing unit into a container.

o

Connect a hose of appr. 80 cm with funnel at the water inlet of the freezing unit.

o

Mix cleaning agent with hot water:

For each freezing unit:   1/2 bottle agent  in 1  litre  water of appr. 50°C     

o

Fill the freezing unit with cleaning agent up to the ice discharge level.

o

Allow the cleaner to react for 10 - 15 minutes. 
This is mostly sufficient.
A maximum of 30 minutes must not be exceeded. 
The cleaner first removes the lime deposit
and then may slightly effect  the metal of the cylinder/auger, if having too long contact.

Do not apply the cleaning agent unnecessarily.

o

Drain cleaning agent and flush freezing unit thoroughly with water.

o

Connect water inlet pipe and switch the machine on.

As the ice may still contain residues of the cleaning agent, we recommend not to use the
ice production of the first minutes of operation, 
though the cleaning agent is admissable for food machinery.

When deposits occur frequently, we recommend the installation of a filter system for the water.
We can offer a three stage filter system, please contact us.

8

Summary of Contents for UBE 1.500

Page 1: ...e quality Miscellaneous 7 Cleaning of freezing unit 8 Wiring diagram attached Cooling circuit General installation advice Assembly Instruction Freezing Unit Spare parts list Subject to technical modif...

Page 2: ...tating auger does not form part of the refrigeration circuit Therefore leakages in the refrigeration system caused by rotating parts cannot occur The ideal ice temperature is 0 5 C ZIEGRA Chip ice has...

Page 3: ...the machine Tighten all electrical connections in the control and at water temperatures above 15 C resp 25 C panel as they may have loosened during the production capacity may decrease transport Cran...

Page 4: ...s full This light barrier has been chosen by us for these 10 Phase sequence Relay particular conditions Please contact us The phase sequence relay switches off the machine if the phases are not connec...

Page 5: ...if necessary V belts check replace if necessary A loose V belt does not transfers the load correctly on the auger This will overload the freezing unit Ice hose and water retainer calcified clean or re...

Page 6: ...eck connection and fuses Fuses blow up Check Intermittent contact Check electrical connections also in control panel Water pressurestat or readjust or replace Water level control defective readjust or...

Page 7: ...cooled machine insufficient water pressure increase water pressure to min 2 bar condenser soiled clean condenser with bottle brush hot water and antilime agent clean water filter water or condensing p...

Page 8: ...ust evaporation temperature as indicated Check thermal feeler pipe and contact at evaporator outlet insufficient amount of refrigerant remove leak evacuate circuit refill bubbles in sight glass with i...

Page 9: ...unit into a container o Connect a hose of appr 80 cm with funnel at the water inlet of the freezing unit o Mix cleaning agent with hot water For each freezing unit 1 2 bottle agent in 1 litre water o...

Reviews: