Safety Information 

!

  Caution!    Refer to the explanation in this Manual 

 

Double Insulation 

This  meter  has  been  designed  to  be  safe  in  use,  but  the 
operator  must  use  caution  in  its  operation.  The  rules  listed 
below should be carefully followed for safe operation. 

1. 

NEVER

  apply  voltage  or  current  to  the  meter  that 

exceeds the specified maximum: 

2. 

USE EXTREME CAUTION

 when working with voltages 

greater than 25VAC rms. These voltages are considerd 
a shock hazard. 

3. 

  NEVER

 operate the meter unless the back cover and the 

battery/fuse door are in place and fastened securely 

Input Limits 

Function 

Maximum Input 

AC Current 

200A 

DC Current 

±200A 

Frequency 

1kHz 

Summary of Contents for ZI-9981

Page 1: ...Operating Instruction 200A AC DC Mini Clamp on Meter www zicotech com ZI 9981 ...

Page 2: ...ation OL displayed on the LCD DCA zero adjust One touch zero key Display rate 2 readings second nominal Battery Two 1 5V AAA batteries Low Battery indication BATT displayed on the LCD Auto OFF approx 7 minutes Operating conditions 32 º F to 86 º F 0 º C to 30 º C 90 RH 86 º F to 104 º F 30 º C to 40 º C 75 RH 104 º F to 122 º F 40 º C to 50 º C 45 RH Storage conditions 14 º F to 140 º F 30 º C to ...

Page 3: ...1Hz 1 2 5 digits Input Sensitivity 5A AC RMS min 51 510Hz 0 1Hz 0 51 1kHz 0 001kHz Non Contact AC Voltage 100VAC to 600VAC 50 60Hz Meter Description 1 Current sense jaw 2 Flashlight button 3 Rotary function switch 4 Data HOLD and Backlight key 5 LCD display 6 Clamp trigger 7 One touch DCA ZERO key 8 Non contact AC voltage indicator light 9 Non contact AC voltage detector probe tip ...

Page 4: ...efully followed for safe operation 1 NEVER apply voltage or current to the meter that exceeds the specified maximum 2 USE EXTREME CAUTION when working with voltages greater than 25VAC rms These voltages are considerd a shock hazard 3 NEVER operate the meter unless the back cover and the battery fuse door are in place and fastened securely Input Limits Function Maximum Input AC Current 200A DC Curr...

Page 5: ... the Function switch to the ACA range 2 Press the jaw trigger and clamp around fully enclosing a single conductor Do not allow a gap between the two halves of the jaw Refer to the diagram at right for the correct way to enclose a single conductor 3 Read the ACA value on the LCD ...

Page 6: ...insert into the hot side of the electrical outlet 2 If AC voltage is present the detector light will illuminate NOTE The conductors in electrical cord sets are often twisted For best results rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources of energy...

Page 7: ...ight key The word HOLD will appear on the LCD while the meter is in the Data Hold mode To release the Data Hold function and return the meter to normal operation press the Hold Backlight key again The word HOLD will switch off Backlight display Press and hold the Hold Backlight key for more than 2 seconds to turn on the backlight This will also activate the Data Hold function To release the Data H...

Page 8: ...When the low battery symbol appears on the LCD the batteries must be replaced 2 Power down and remove the rear battery compartment Phillips screw 3 Lift off the battery compartment cover and replace the two 1 5V AAA cells 4 Replace compartment cover and secure the screw www zicotech com ...

Reviews: