Zico ZI-9679 User Manual Download Page 4

 

LCD interface instruction 

 

a.

 

Scan symbol 

b.

 

Measure data 

c.

 

Temperature value for Max/Min 

d.

 

Data hold symbol 

e.

 

Laser on symbol 

f. Lower power symbol 
g. C/F symbol 

 

Measurement operation   

 Hold the meter by its 

Handle Grip

 and point it toward the surface to be measured. 

 Pull and hold the 

Trigger

 to turn the meter on and begin testing.   

  Release  the  Trigger  and  the  HOLD  display  icon  will  appear  on  the  LCD  indicating  that  the 

reading  is  being  held.  In  HOLD  status,  press  the  MAX/MIN  button  to  display  maximum  and 
minimum measurement points in the last measure. 

 The meter will automatically power down after approximately 10 seconds without use. 

Switching C/F   

Short press the C/F button 

Switching Max/Min 

Press the Max/Min button. 

Switch on/off laser and backlight 

Short press the 

Laser/ Backlight

 button to turn on/turn off the l backlighting. 

Long press the 

Laser/ Backlight

 button to turn on/ turn off the laser. 

When the laser is on the laser icon will appear on the LCD over the temperature.   

 
 

Summary of Contents for ZI-9679

Page 1: ...cts which are uneasy to be touched Proper use and care of this meter will provide years of reliable service FEATURES Rapid detection function Precise non contact measurements Single laser sighting Unique flat surface modern housing design Automatic Data Hold MAX MIN function Wide range application Food preparation Safety and Fire inspectors Plastic molding Asphalt Marine and Screen printing measur...

Page 2: ...target the closer you should be to it When accuracy is critical make sure the target is at least twice as large as the spot size SPECIFICATIONS 50 to 500 58 932 Temperature range 12 1 D S 0 1 0 1 Display resolution Fixed at 0 95 Emissivity for targets 3 5 4 2 0 2 3 6 Accuracy 50 20 58 68 20 500 68 932 1 1 8 Repeatability 500ms Response time 8 14um Spectral response LCD will show Over range indicat...

Page 3: ...3 Panel description Button instruction 1 Power on Measure button automotive switch off about 10 seconds 2 Laser Backlight button 3 C F 4 Max Min button 5 Display screen ...

Page 4: ...n the LCD indicating that the reading is being held In HOLD status press the MAX MIN button to display maximum and minimum measurement points in the last measure The meter will automatically power down after approximately 10 seconds without use Switching C F Short press the C F button Switching Max Min Press the Max Min button Switch on off laser and backlight Short press the Laser Backlight butto...

Page 5: ...ver back Note In case of long term storage is recommended to remove the battery Last date to use mention on the battery Battery provided with the instrument is Non rechargeable battery Keep all batteries away from children and animals swallowing a battery can be fatal in which case you should seek immediate medical attention Keep batteries away from direct sunlight high temperature and high humidi...