Zibro SRE 130 TC Operating Manual Download Page 6

Check the removable tank fuel gauge 

H

while filling the tank (Fig. D). Stop 

filling by loosening the switch button on top of the pump (turn anti-clock-

wise), once the gauge indicates that the tank is full. Never overfill the tank, 

especially not when the fuel is very cold (fuel expands when it heats up).

Let the remaining fuel in the pump flow back into the jerrycan and carefully 

remove the pump. Carefully screw the fuel cap back on the tank. Clean off 

any spilled fuel.

Check whether the fuel cap is straight and tightened properly. Reinstall the 

removable tank in the heater (cap down). Close the lid.

C

SETTING THE CLOCK

It is only possible to set the correct time, when the heater is connected to the

mains and not burning. Use the adjustment keys 

P

to set the time. First press

either of the two keys to switch on the function (the 4-digit 

M

will start blinking).

Next, set the hours using the key on the left (

N

hour) and the minutes using the

key on the right (

M

min.). Press once to increase the value by one step. When you

hold down the key, the value will continue going up, until you release the key

again. After approximately 10 seconds the 4-digit will stop blinking and the

setting will be locked. 5 minutes after switching off the heater, the information on

the display will disappear and the heater will automatically switch into the stand-

by position.

When the heater has been unplugged (or after a power failure), the time needs

to be set again. 

D

IGNITING THE HEATER

When used for the first time, a new heater may give out a smell for a short while.

You should therefore provide extra ventilation. Always ignite the heater with the

button 

N

. Never use matches or a cigarette lighter.

Just press the 

button 

N

to ignite the heater. The button will start blinking,

indicating that the ignition procedure has started. This will take a short while. Once

the heater is burning, the 

button 

N

will remain lit (red). The information display

M

will show two numbers. The light next to them indicates that these numbers

refer to the temperatures (Fig. F). The actual room temperature is indicated below

ROOM, while the temperature setting is indicated below SET. The latter can be

changed with the adjustment keys (refer to Section E).

Prior to igniting the heater, always check for sufficient fuel in the removable tank.

E

SETTING THE REQUIRED TEMPERATURE

The temperature setting can only be adjusted, when the heater is burning. Use the

adjustment keys 

P

to adjust the temperature. First press either of the two keys to

switch on the function (the °C mark and 4-digit 

will start blinking). Next, adjust

the temperature using the key on the right (

M

min.) to set the temperature to a

higher setting and the key on the left (

N

hour) to lower the temperature. Press

once to increase the value one step. After approximately 10 seconds the °C mark

and 4-digit will stop blinking and the setting will be locked (Fig. F).

8

7

6

4

46

D

empty

full

F: The required

temperature on the left,

the measured

temperature on the

right.

E: When the 4-digit stops

blinking, the setting has

been locked to the

indicated value.

Summary of Contents for SRE 130 TC

Page 1: ...SRE 152 TC 2 12 22 32 42 52 62 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING 3 2 6 5 4 1...

Page 2: ...ons for Use first to ensure maximum lifetime for your heater Your heater comes with a 48 month manufacturer s warranty on all defects in materials or workmanship We wish you a warm and comfortable tim...

Page 3: ...up all the remaining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Fuel gauge removable tank Air filter Vent filter Thermo...

Page 4: ...i e oxygen the heater will automatically switch off Do not use your heater in cellars or other underground areas THE RIGHT FUEL Only use Class C1 paraffin fuel in accordance with BS2869 Part 2 or equi...

Page 5: ...P refer to Section C Your heater is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedu...

Page 6: ...set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the butto...

Page 7: ...ff the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button N once to clear the timer setting G SWITCHING OFF THE HEATER There are tw...

Page 8: ...clean again the heater will automatically switch back to the highest setting again I CHILDPROOF LOCK The childproof lock can be used to prevent children accidentally changing the heater settings When...

Page 9: ...contact your dealer M MAINTENANCE Switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains Your heater needs hardly any maintenance It...

Page 10: ...transportation cap into the position of the fuel filter Fig N Press it tight Always move the heater in an upright position P SPECIFICATIONS Ignition electrical Dimensions mm width 374 Fuel paraffin in...

Page 11: ...powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move the heater when it is burning or still hot Do not refill nor servi...

Page 12: ...E E E E E E E E E E E E E E E E E E E E E E E E...

Page 13: ...E E E E E E E E E E E E E E E E E E E E E E E E M N A E G F D K B C J L I H Q P E P R O...

Page 14: ...40 ESPOO tel 358 9 4390 030 fax 358 9 4390 0320 email appliance appliance group com 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 83778...

Reviews: