-77-
Explanation 7
If the Igniter is broken or if the terminal is disconnected, the fuel is
fed into the Burner even without having the source of flames. Do
not, therefore, repeat ignition operation for many times, which
otherwise causes kerosene at the bottom of the Burner.
It is,
therefore, necessary to completely remove kerosene as well as to
removing the cause of the trouble.
Also refer to Explanation 3 of E-1 Display.
Explanation 8
• The Heater operation may be stopped in a similar way to that
without flames, if the connector of the Flame Rod is not
connected securely.
• The Flame Rod is securely fixed to the Burner, after making sure
that the Flame Rod is provided with the Gasket properly. (See
page 28 for the details by model.)
E-5 DISPLAY
CAUTION
No overhauling of the Tip-over Switch is permitted.
E-5 is displayed and the
heater is extinguished.
The Tip-over Switch has
been actuated.
When
an
earthquake
occurs.
Repair or replacement of
the part.
Give a re-ignition.
Failure
of the
Tip-over
Switch.
When moving the Heater
or tilting the Heater.
When
the
Heater
is
subjected to a strong
vibration or a shock.
Non-conforming wiring.