4
1. Introduction
Summary
The Zibra Handheld Light Source (HLS) provides superior LED illumination for endoscopes, borescopes,
video scopes, veterinary and dental examination applications. Patent pending optics collect more light from
the LED, for a highly efficient light source. The Zibra HLS replaces fiber-optic light-guide cables or wires
common to traditional light sources of the past. Enhanced mobility, ease of use, brightness and quality of
light are achieved with this device. It uses a powerful, best-in-class LED, cooled by a comfortable, finned
handle. An easy to grip intensity knob provides precise adjustments of light output and a quick-change
battery. Internal circuitry protects against accidental reverse polarity, should the battery be inserted in the
wrong orientation, and maintains constant current to the LED as the battery voltage drops with use, for more
consistent light output. A long life LED eliminates lamp replacement and requires no fan, providing a silent
and energy efficient light source which is lightweight, compact and portable.
Please be sure to handle this optical instrument with care at all times. The electrical and optical components
can be damaged by physical abuse, extreme temperatures, or fluid invasion into the light source.
IMPORTANT
: This instrument is intended for use by persons thoroughly trained in the
techniques that employ this light source, such as endoscopy.
WARNING:
Avoid direct viewing of the high intensity light at the front of the Handheld Light
Source. Never poi
nt it’s light at other’s.
This manual describes the proper procedures for using the light source. The manual also contains pertinent
information on the proper care and handling of the light source during use, disinfecting and storage.
Please read this entire manual carefully before using the light source. If you have any questions concerning
the material contained in this manual or the operation or safety of the equipment, please contact Zibra.
Safety Measures
•
Never look directly into the light source when it is on. Point its light away from others.
•
Read this Owner’s Manual first. Improper use may damage the light source.
•
Check all items upon receipt to assure damage has not occurred during shipment.
•
Verify compatibility of all scopes and accessories attaching to the HLS by contacting Zibra.
•
Avoid storing or charging the HLS in areas of heavy traffic to prevent accidental physical damage.
•
Do not disassemble the HLS. There are no user-serviceable parts. Disassembly voids all warranties.
•
Avoid immersing the light source for periods of time greater than recommended by the disinfectant
manufacturer. Prolonged immersion may damage the exterior of the light source and could result in
fluid invasion into the light source.
•
Prior to use, check the outer surface of the light source, endoscope and any endoscopically-used
accessories for rough surfaces, sharp edges, burrs or protrusions that may cause a safety hazard.