ZHURUI EM20 User Manual Download Page 3

ZHURUI

                             Shenzhen Zhurui Technology Co.,Ltd.

 

  3  /  11 

Product overview 

EM20 energy monitor use 2.8-inch TFT color LCD, it can monitor the household appliances’ power, power factor, 

voltage, current, frequency, total electricity consumption, elapsing of time and electricity fees, electricity consumption at one 

time, elapsing of time and electricity fees at one time. It records electricity consumption and fees every day, you can see the 

historical data in the form of charts or lists. EM20 energy monitor is suitable for detecting and recording the operation and 

energy  consumption of household, factory, office and other electrical equipment, it  can turn on or off the power supply 

(external relay version only) at a set time 

(Note 1)

 

Main characteristics

 

 

Digital operate and control;

 

 

2.8-inch TFT color LCD display; 

 

0.5FS measuring accuracy; 

 

Chinese and English can be set freely; 

 

23 money units can be set;

 

 

6 touch buttons for setting;   

 

The date can be set and the time can be set with 5 forms; 

 

It can be set automatically to be power on, power off, or keeping the working state after the last power off

(Note 1)

 

Electricity includes total electricity and one-shot electricity,

 

one-shot electricity can be cleared, in order to measure 

the electricity and cost in some situation;   

 

In working condition, there are 4 main pages for choosing: General view, Total Electricity, One-shot Electricity, 

Realtime Electrical Parameter. The default is

 

General view, user can press”

” or”

” to switch the different pages; 

 

It records automatically the history data of electricity: elapsing of time, electricity consumption and electricity fees 

by list or chart, it can store the data for more than 30 years;   

 

Electricity tariff support 4 decimals, the decimal point can be set to 0 between 4. It supports 3 charges: simple 

tariff,

 

time-sharing tariff and stage tariff. Time-sharing tariff support 8 time periods to calculate the cost, which can 

be used for peak and valley billing. Stage tariff support 8 stages power rates. You can set the date that begin to 

charge the stage billing 

 

It has 9 timers, in which 2 are advanced. They can be set the specific time, date, working day or weekend to open 

or close the switch. The other 7 timers can be set to open or close the power at the specific time in a day.

 (Note 1)

   

 

It has the function of alarm, you can set values for voltage, current, or power. If they were exceeded, the monitor 

will alarm automatically; 

 

It can protect itself by cutting off the power supply when the voltage, current, or power exceed the set value; it 

has automated recovery function. After this function was selected, when the monitor is in the output protection 

mode. 1 minutes later, it will open the power automated, if the value exceeds the set, it will cut off the power again 

to protect itself. 

(Note 1)

 

 

Energy-saving setting: you can set that the screen will be closed without any action in 1minute, 5 minutes, or 10 

minutes,  or  the screen can  be  set not  to be  closed.  Even  if the screen was closed, which not influence the 

monitor’s measuring. If any button is touched, the screen will be opened again; 

 

It has the function of clearing the total electricity, history data and factory reset; 

 

The power resolution can be switched automatically. When the power <1000W, it has one decimal, the unit is W; 

When the power <10kW, it has 3 decimals; the unit is KW; When the power >10kW, it has 2 decimals, the unit is 

KW; 

 

If the measured is overrange, it will show “High” on the screen; 

 

It supports 1000:1 or 2000:1 current transformer, the max current of the transformer is 120A; 

 

Only support single coil magnetic latching relay;

 (Note 1)

 

 

Mounting box type 86 is used. 

Note 1: Only external

 

relay version has this function. 

Summary of Contents for EM20

Page 1: ...User Manual EM20 Energy Monitor Shenzhen Zhurui Technology Co Ltd...

Page 2: ...r manual carefully Packing lists 1 EM20 energy monitor 1pcs 2 Current Transformer 1pcs 3 User Manual 1copy 4 Warranty Card 1copy 5 Product Certificate 1copy If the machine is out of work please contac...

Page 3: ...to 0 between 4 It supports 3 charges simple tariff time sharing tariff and stage tariff Time sharing tariff support 8 time periods to calculate the cost which can be used for peak and valley billing...

Page 4: ...e function The model of this monitor EM20 ER Energy Monitor External relay or not Blank No external relay ER With external relay Technical Index Electrical Parameters Parameter Measuring range Resolut...

Page 5: ...ion 1 minute The currencies of electricity fee Currency name CNY TWD USD EUR GBP JPY RUB INR Currency symbols Rs Currency name KRW TRY THB PHP IDR MYR ZAR AED Currency symbols Rp RM R Currency name SA...

Page 6: ...magnetic latching relay If it is found that the relay is disconnected when it needs to be powered on and connected when it needs to be powered off it is necessary to exchange terminal 5 and 6 wiring...

Page 7: ...ears in the status bar when switched to the main page 3 Main page 4 icon It appears in the status bar when switched to the main page 4 The buttons The buttons Function The main page The setting page k...

Page 8: ...ess key again to see the history pages The history record page Month chart Month list Year chart Year list The function setting process e g the machine connected the external relay Go into the setting...

Page 9: ...setting Currency setting Simple tariff Time sharing tariff Stage tariff Date format Time setting Special timer setting Only external relay version Common timer setting Only external relay version Swit...

Page 10: ...rotection setting If necessary change the corresponding output protection setting value or cancel the corresponding output protection setting or check the Launch overload check box Only for external r...

Page 11: ...y Co Ltd and it may exist license unless with the written permission of related rights otherwise any person cannot be allowed to copy distribute copy board decompile disassemble decrypt reverse engine...

Reviews: