background image

.                                                                     

 

 

 

Operation Manual    (ChinaZTT)

 

 

GPF-01 Fiber Optic Cable Termination Box 

 

Applications:   

This product is applied to joint the end of optical cable and 
termination  equipment  by  pigtail  after  the  optical  cable  of 
48 fibers maximum capacity enters equipment room.     

 

 

Structure: 

Wall mount termination box has a quadrate metal cover. There 
are the cables entrance holes or divergent holes on two sides 
of the box. This termination box is assembled by fiber splice 
tray, pigtail fiber coiling device and optical fiber connector, etc.   

 

Technical Specifications:   

Size (mm): 340 x 300 x 125        Weight: 1.5kg 
 

Main Technical Performance: 

1.  It has the pulling function for ground wire connected with optical cable sheath.   
2.  It has the fixing function for optical cable strengthen core and can endure 500N tensility. 
3.  Fiber  bending  radius  in  the  tray  doesn’t  affect  fiber’s  normal  use.  Tray-retaining  fiber 

length>1.6m.   

 

Installation Method:   

1.  Open termination box’s upper cover and take off the cover of optical fiber splice tray.   
2.  Peel the optical cable and retain enough loose tube length. Pull optical cable into termination box 

and fix it with two clamps. Then fix the metallic strengthen core.   

3.  Use alcohol cotton to wipe and clean fiber lightly. Then coil the fiber in the fiber coiling board. 

Randomly put 

thermal shrinkage

 tube on one of pre-connection two fibers. After welding, move 

the thermal shrinkage tube to make fiber welding-point set in the center of tube. Heat the thermal 
shrink tube to make the tube and fiber fuse together. Press the protected fiber joint into the fiber 
laying groove.   

4.  Arrange  retaining fiber  into  the fiber-laying groove  equally.  Generally,  arrange  it from  lower  to 

upper. After splicing all the fibers, put the cover on the most upper layer.   

5.  Link  pigtail’s  flexible  end  with  the  connector.  Then  coil  and  neaten  the  surplus  pigtail  on  the 

wire-coiling device.   

6.  Use the pigtail to link the connector with the equipment room.   
7.  Use the expansion snail to fix the termination box on the wall. 

 