(1)  Learn / erase remote controls 

Adding extra remote controls (Learn): Press red button on the control board (see Fig.14 No.12), then 

the ‘LED’ (see Fig. 14 No.11) will be on, it will turn off when you press any remote control button. 

Press the same button, the ‘LED’ will flash at 2Hz frequency and then turn off; this indicates the 

learning process is finished. If it fails to set, the ‘LED’ will turn off automatically after flashing for 1 

second, you should follow the steps above to reset. 

Up to 25 remote controls may be used. 

To erase all remote controls: press and hold the red button on the control board until ‘LED’ turns on 

and then turns off. This indicates that all the remote controls have been erased completely. You 

should reprogram the remote control if you want to control this opener (see Adding extra remote 

controls section). 

(2) The remote control works in a single channel mode. It has four buttons. See Fig. 13. With each 

press of the remote control button which has been programmed, the gate will close, stop, open or 

stop cycle. 

Warning: Notify the users that the gate is never to be operated unless it is in full view. 

(3) Operation of the gates 

The gates can be controlled by using remote control, single-button mode or three-button mode   

external button switch.   

z

 

Unlock the gate opener with the key. Push the gates to the opened (retracted) position manually. 

Lock the gate opener with the key 

z

 

Turn the power on. 

z

 

Close the gates by using remote control, single-button mode or three-button mode external 

button switch. The No.2 gate-leaf will close first, and then the No.1 gate-leaf with electrical lock 

will close after 3 seconds.   

z

 

The gates will stop at its closed position automatically, or you can stop the gates at its closed 

position by remote control, single-button mode or three-button mode external button switch. If 

gates do not stop or bind before stopping, verify that the stop is firmly in place, and the force 

adjustment knob for that gate on the control board is adjusted correctly. Adjust counter-clockwise 

to reduce binding. 

z

 

Open the gates by remote control, single-button mode or three-button mode external button 

switch. Firstly, the electrical lock will be opened, the No.1 gate-leaf with lock will open, and then 

the No.2 gate-leaf will open after 3 seconds. 

z

 

The gates will stop at its opened position automatically, or you can stop the gates at its opened 

position by remote control, single-button mode or three-button mode external button switch. If 

gates do not stop or bind before stopping, verify that the stop is firmly in place, and the force 

adjustment knob for that gate on the control board is adjusted correctly. Adjust counter-clockwise 

to reduce binding. 

z

 

Total working time: 24 seconds. 

Note: 

The gate will return to open if press ‘OPEN’ button on the three-button mode external button 

switch during closing, the beeper will ring. We call this

 Open priority

 

 

 

Summary of Contents for K207A

Page 1: ...K207A SWING GATE OPENER USER S MANUAL ZHEJIANG XIANFENG MACHINERY CO LTD ...

Page 2: ...ration z Children should not be allowed to play near or operate automatic gates z The maximum force that the gate opener can provide is 1500N z An electric lock is provided for installation for gate lengths greater than 5 feet 1 5 meters z This unit uses a current feedback system to stop Do not operate the opener without a solid stop block in place This could cause injury damage to the opener or o...

Page 3: ...top and reverse if it encounters an obstruction during closing and stop when it encounters an obstruction during opening z Manual key release design for emergency purposes Specifications z Power Supply AC220 1 10 V 50Hz z Motor Speed 1400 rpm z Motor Output AC220V 110W z Electronic Lock Output DC12V 2A z Relay Coil Voltage DC12V z MCU Voltage DC5V z Remote Control Range 30m Hopping Code z Control ...

Page 4: ...ral gear 26 Planetary spindle 27 Corrugated gasket 28 Circlip 29 24T planet carrier 30 Bearing 61800 31 Elastic circlip 19 32 24T ring gear 33 Bearing 61800 34 Locating shield 35 Pin 4x20 36 Coupling joint 37 Motor 38 Capacitor bracket 39 Capacitor 40 Wiring base 41 Wiring terminal 42 Screw M4x8 43 Wiring cover 44 TappingscrewST3x13 45 Joint block 46 Axle pin 47 Earth wire 48 Release key 49 Lock 5...

Page 5: ...to open or a pull to open installation In either configuration the gate is mounted on one face of the mounting post and the opener is mounted on the face 90 degrees from it Below are schematics of both push to open and pull to open configurations Fig 1 Push to Open α α Close Open Fig 2 Pull to Open Gate opener Enlarge α α Close Open ...

Page 6: ...meet the specifications shown in figure 3 See Fig 3 Fig 3 Retainer close position Gate opener Retainer open position Cmax A B 0 110 1020 α A B Cmax 140 130 115 125 50 50 90 105 Enlarge α Main Structure Fig 4 Special motor Planetary reducer Screw shaft Control box ...

Page 7: ...hes 300 800mm See Fig 5 Fig 5 Electric lock Gate Gate opener Gate post Front and Rear Parts of Gate Opener To install the rear part of the gate opener insert shoulder screw and spacer then tighten with the nut See Fig 6 Fig 6 S houlder screw S pacer N ut gate opener S upporting bracket ...

Page 8: ...mer and finally fit the retainer clip See Fig 7 Fig 7 Retainer clip Front part of gate opener Axle pin Supporting plate Wiring Screw off the two stainless tapping screws and then remove the cover and wiring as shown in Fig 8 WARNING Follow the wiring diagram precisely Failure to do so could cause damage to the gate opener controller Fig 8 M V U W Upper cover Enlarge Stainless tapping screw ...

Page 9: ...proof caps There are 8 caps in total 4 to be used and 4 spares When the gate opener is installed the caps are used to cover the upper holes of the unit to avoid leakage See Fig 10 Fig 10 W a te rp ro o f c a p G a te o p e n e r Retainer Closed and Opened Positions Close the gate section to its fully closed position fix the retainer according to the position of the gate section NOTE Each section i...

Page 10: ...k Weld the steel plate of the lock to the gate and then fix the lock See Fig 11 to determine the height of the plate Fig 11 A Release here Electric lock Base plate To install the base plate of the lock fix the plate to the ground with 3 screws and make sure that the lock pin can fit tightly in the hole in the plate Adjustment The pair of gate sections will not start simultaneously The gate section...

Page 11: ... be set into the concrete when it is poured Wires within the cable shall be located or protected so that no damage can result from contact with any rough or sharp part The diameter of the cable should be more than 20mm the wire size inside the cable should be more than 1 0mm2 2 Install the control box z The control box circuit should be equipped with single phase breaker 10A z Make sure that power...

Page 12: ...h or keypad To install the keypad attach two wires of your keypad to the O S C terminal The keypad will function in single channel mode For three button switch installation use the terminals for multi channel mode Three button mode The port GND is the common port the port OP is used to open the gate CL is used to close the gate and ST is used to stop the gate Single button mode connect two wires o...

Page 13: ...ned retracted position manually Lock the gate opener with the key z Turn the power on z Close the gates by using remote control single button mode or three button mode external button switch The No 2 gate leaf will close first and then the No 1 gate leaf with electrical lock will close after 3 seconds z The gates will stop at its closed position automatically or you can stop the gates at its close...

Page 14: ...ating clockwise will increase the resistance needed to trip the safety reverse function Rotating counter clockwise will decrease the resistance If the gate does not move when activated or auto reverses without striking an obstacle then the resistance setting may be too little If the gate does not stop when an obstruction is placed in its path then the setting may be too high 5 Auto close function ...

Page 15: ...K207A Swing Gate Opener User s Manual Fig 14 control board diagram ...

Page 16: ...lockwise 6 Beeper 12V 7 Antenna Impedance 50Ω 8 Receiver panel Receive signals 9 Memory card It can be unplugged it is used to store signals 10 Power indicator light LED1 1206 green 11 Indicator light LED 1206 red 12 Learn button 6 6 red 13 Dip switch Set auto close function 14 External device interface Connect infrared device 15 External button switch keypad interface Connect external button swit...

Page 17: ...st FORCE ADJ clockwise to increase force 2 Remove obstructions Remote control does not work 1 The indicator light of remote control does not light 2 Remote control is not suitable for receiver 3 Receiver panel 1 Battery level may be low replace the battery inside the remote control 2 After making sure the codes are correct erase remote controls and then re program the remote control 3 Check the re...

Reviews: