Zhejiang
Zhejiang
Zhejiang
Zhejiang Feishen
Feishen
Feishen
Feishen Vehicle
Vehicle
Vehicle
Vehicle CO.,
CO.,
CO.,
CO., LTD
LTD
LTD
LTD....
13
13
13
13
/
26
26
26
26
Dual
Dual
Dual
Dual Rates/Exponential
Rates/Exponential
Rates/Exponential
Rates/Exponential Settings
Settings
Settings
Settings
The aileron, elevator and rudder dual rates on the FSH62832 are simultaneously activated
by the dual rate switch. The amount of travel decrease for each control may be set
between 0% and 100% of the values set for the end points (explained in End Point
Adjustment on page 14).
Note
Note
Note
Note
: It is possible to set a dual rate value to zero, thus causing no response from that
channel. If the dual rates are inadvertently set to zero, a crash could result.
Note
Note
Note
Note
: When performing initial model setup, the E.P.A.s should be set
prior
prior
prior
prior to
to
to
to
setting the
dual rates. When setting the E.P.A.s for the first time on a new model, the dual rates
should be set to 100%.
.
D/R
D/R
D/R
D/R Dual
Dual
Dual
Dual Rate
Rate
Rate
Rate Settings
Settings
Settings
Settings
To
To
To
To select
select
select
select the
the
the
the Switch/position
Switch/position
Switch/position
Switch/position to
to
to
to control
control
control
control the
the
the
the dual
dual
dual
dual rates:
rates:
rates:
rates:
1
、
Enter
the programming mode,
press
MODE"
MODE"
MODE"
MODE"▲
▲
▲
▲"
""" or
or
or
or "
"""▼
▼
▼
▼"
"""
key
to access D/R programming mold
2
、
Press the
“
“
“
“SELECT
SELECT
SELECT
SELECT”
”
”
”
key to choose the desired channel
(1-aileron, 2-elevator, 4- rudder). The channel number appears
on the left side of the screen
Note
:
if an
“
“
“
“EXPO
EXPO
EXPO
EXPO”
”
”
”
is shown on the screen, that means you press
“
“
“
“SELECT
SELECT
SELECT
SELECT”
”
”
”
too long,
and access
“
“
“
“EXPO
EXPO
EXPO
EXPO “
“
“
“
set mode. Press
“
“
“
“SELECT
SELECT
SELECT
SELECT”
”
”
”
to get back to dual rate setting.
3
、
Place the dual rate switch (selected previously) in the desired position for the value you
wish to change. (generally, pilots prefer to have the switch in the “up” position for the high
rate, and in the
“
“
“
“down
down
down
down”
”
”
”
position for the low rate.
4
、
Change the dual rate value for the respective channel using the
DATA
DATA
DATA
DATA “
“
“
“+
+
+
+“
“
“
“ or
or
or
or “
“
“
“----”
”
”
”
lever
until the desired control throw is achieved. If you wish to change the control throw when
the switch is in the other position as well, move the switch accordingly, then use the
DATA
DATA
DATA
DATA
“
“
“
“+
+
+
+”
”
”
” or
or
or
or “
“
“
“----“
“
“
“
lever to change the throw rates.
5
、
Repeat procedure 3 and procedure 4 to set the dual rates for other channels.
(channel 2-elevator, channel 4-rudder)
Exponential
Exponential
Exponential
Exponential Settings
Settings
Settings
Settings
Exponential, or
“
“
“
“EXPO
EXPO
EXPO
EXPO “
“
“
“
as it is commonly abbreviated,
affects the travel of the servos around their center in
relationship to stick movement. Exponential does NOT
impact the overall travel volume of the servos. A negative
“-“ exponential input will soften or reduce the servo’s
movements near the control’s neutral position. A positive “+”
exponential input will increase the servo’s movements near the control’s neutral position.
Exponential set could between -100% and +100%.