background image

Manual

Version: VE-2021-001

KXN Series Switching DC Power Supply

Summary of Contents for KXN Series

Page 1: ...Manual Version VE 2021 001 KXN Series Switching DC Power Supply...

Page 2: ...of Constant Voltage Constant Current Function Description Model B Constant Voltage Operation Constant Current Current Limit Setting Operation Voltage and current calibration operation Function Descrip...

Page 3: ...t be available for the user at any time Do not open the cover Do not operate this product with the outside cover or panel open Do not operate the product when you suspect that it malfunctions If you s...

Page 4: ...1A in some models Low noise Temperature controlled fan is adopted and it starts automatically to dissipate heat when internal temperature is greater than 50 Start Guide Standard Accessories and Select...

Page 5: ...Product Size C model Product Size D model 3...

Page 6: ...2mV Load stability 0 35 3mV Voltage stabilization degree 0 2 2mV Load stability 0 2 2mV 4 Preface Technical Parameter Tab 1 Tab 2 0 1 2mV 0 2 2mV Type KXN 155D KXN 305D KXN 645D Input voltage AC 220V...

Page 7: ...age stabilization degree 0 2 2mV Load stability 0 35 3mV Voltage stabilization degree 0 2 2mV Load stability 0 2 2mV Tab 3 Tab 4 0 1 2mV 0 2 2mV Type KXN 155DM KXN 305DM KXN 645DM Input voltage AC 220...

Page 8: ...tion Voltage 0 1V Current 0 1A Boundary dimension 366 depth 198 width 158 height Weight 3 9KG 3 85KG 4 6KG 4 6KG 5 7KG 5 8KG Tab 5 Type KXN 3020D KXN 3030D KXN 3040D KXN 6010D KXN 6020D Input voltage...

Page 9: ...7 Type KXN 1004D KXN 1005D KXN 1201D KXN 1202D KXN 1203D KXN 1205D Input voltage AC 220V 10 50Hz AC 110V 10 60Hz AC 240V 10 50Hz Temperature Working temperature 10 40 Relative humidity 80 Storage tem...

Page 10: ...ltage 4 digit 0 3 Current 3 digit 1 LED 1 character Preface Technical Parameter 1 2 1 Voltage Current 4 digit 0 3 2 332 depth 198 width 158 height Type KXN 2001D KXN 2002D KXN 2003D KXN 2005D KXN 3001...

Page 11: ...ht Weight 3 4KG 3 45KG 4 3KG 4 4KG 5 3KG 4 5KG Tab 12 Voltage 4 digit 0 3 Current 3 digit 1 LED 1 character Type KXN 3003D KXN 3005D KXN 4001D KXN 4002D KXN 4003D KXN 4005D Input voltage AC 220V 10 50...

Page 12: ...KG 8 5KG 8 8KG 11KG Tab 14 Voltage 3 digit 1 Current 3 digit 1 LED 1 character Type KXN 8001D KXN 8002D KXN 10001D KXN 10002D Input voltage AC 220V 10 50Hz AC 110V 10 60Hz AC 240V 10 50Hz Temperature...

Page 13: ...ension 378 depth 260 width 160 height Weight 6 8KG 8 5KG 8 8KG 8 8KG 13KG 13KG Tab 16 Voltage 3 digit 1 Current 3 digit 1 LED 1 character Type KXN 4860D KXN 5030D KXN 5050D Input voltage AC 220V 10 50...

Page 14: ...dimension 460 depth 260 width 160 height Weight 13KG 11KG 12KG 15KG 8 5KG 8 5KG Tab 17 Voltage 4 digit 1 Current 4 digit 1 LED 1 character Type KXN 30150D KXN 30010D KXN 40010D KXN 15030D Input voltag...

Page 15: ...ation from each connection point In some cases the connection point must be exposed which may cause physical contact In this case operators must be trained to know how to protect themselves from the r...

Page 16: ...it 4 For more help please contact zhaoxin Output Check The following steps are used to check whether power supply produces rated output and whether it can correctly respond to operations from the fro...

Page 17: ...Current ne adjustment knob current display clearing 3 Current coarse adjustment knob sound on o 4 C C constant current indicator 5 Power on o 6 Output terminal negative 7 Ground terminal 8 Output term...

Page 18: ...coarse adjustment knob current display clear 4 C C constant current indicator 5 Power switch 6 Output start on o 7 Output terminal negative 8 Ground terminal 9 Output terminal positive 10 Voltage righ...

Page 19: ...1 Cooling fan 2 AC power connector 3 AC fuse box 1 High power output terminal in some models 2 AC power connector 3 AC fuse box 4 Cooling fans 1 High power output terminal in some models 2 AC power co...

Page 20: ...nt voltage mode C C Indicator on the front panel is red C C The current output will be constant at the preset value and output voltage will vary with the load When the output current is less than the...

Page 21: ...ant Current Current Limit Setting Operation For example set constant current or current limit to 3A Steps 1 Current setting Use coarse ne adjustment knob of current to set the current to 3A and the cu...

Page 22: ...the coarse adjustment knob of the current for the low side starting point calibration of the constant current value Set the electronic load under the constant current CC mode and start it by outputti...

Page 23: ...e adjustment knob of current for 3s to turn o the sound If you need to turn it o please repeat the above operation to turn on knob sound Display shift Shift the display by short pressing voltage or cu...

Page 24: ...tting Use coarse ne adjustment knob of current to set the current to 10A and the current displayed is preset current at this time 2 Connect the load When output current is greater than or equal to 10A...

Page 25: ...the Output button to output Function Description Model D Knob sound on o in standby long press adjustment knob of voltage for 6s to turn o the sound If you need to turn it o please repeat the above o...

Page 26: ...e adjustment knob of current to set the current to 20A Note current displayed is preset current at this time 2 Connect the load and press the Output button to output When output current is greater tha...

Page 27: ...d whether there is a problem with the load Abnormal constant current output 1 Check maximum output power meets load requirements or not 2 If it is satis ed please check whether voltage setting value i...

Page 28: ...haoxin Electronic Instrument Equipment Co Ltd Address F 4 Building 3 Tianli Industrial Zone Xueyuan Road Longxi Community Longgang Subdistrict Longgang District Shenzhen Marketing Center Shenzhen Zhao...