Installation
025-9416
79
5. If an SSC is not working, check that the CPA line jumper is set for CPA to CPA, not CPA to CPB.
6. The following parameter settings are typical in the Model 640 database. In the Transmitter Key Type database
set:
ModeTime = 50 ms
BusyTime = 25 ms
StaRmtCtrl = RTS/CTS
DigDataPolarity = “0” for inverted data
In the Transmitter Key Up Control database set:
ModeSgnlPlrty = “high” for digital
Transmitter Controllers
Transmitter controllers are used between the paging input (either directly from the paging term-
inal or on an RF/microwave downlink) and the paging transmitter. The transmitter controller
governs how the transmitter sends out pages. It can determine whether the pages are analog or
digital and demodulate the FSK signals from the paging terminal (in digital mode).
Model 66 Transmitter Controller Interface
At the radio site, a Zetron Model 66 Transmitter Controller provides the remote paging trans-
mitter interface by way of telco line or
µ
wave/RF link. The Model 66 controls analog and digital
paging for transmitters from Quintron, General Electric, Glenayre, Neutec, Spectrum, and other
manufacturers. The Model 66 supports both PURC® and dual-frequency tone remote operation.
See Figure 37 and Figure 38 for basic system applications requiring a transmitter controller.
Figure 43 illustrates the direct cable hookup between the Model 66 and a generic paging trans-
mitter. The link input (RF, microwave, or telco) to the Model 66 should be connected to the
FROM LINK pins (J3 - 4, 5) on the rear panel of the transmitter controller. Refer to the
Model 66
Transmitter Controller Operation and Installation Manual
(Part No. 025-9078) for more details.
Model 66
Transmitter Output
(J2)
Paging
Transmitter
Signal Inputs
TO TX HI
(2)
UNNOTCHED AUDIO
ANA PTT N/O
(4)
LOCAL PTT
DIG PTT N/O
(7)
DIG DATA
(10)
DIGITAL DATA
DIG MODE
(11)
DIGITAL RTS
TO TX LO
(1)
ANA PTT COM
(5)
DIG PTT COM
(8)
GROUND
(3)
GROUND
Figure 43. Wiring Configuration for Model 66 Transmitter Controller
Note:
The polarity for the DIG DATA and DIG MODE outputs is selected with jumpers
(JP3 and JP2) in the Model 66.
Summary of Contents for 640 DAPT XTRA
Page 2: ......
Page 6: ...Statements vi 025 9416...
Page 20: ...Introduction 8 025 9416...
Page 26: ...Specifications 14 025 9416...
Page 96: ...Installation 84 025 9416...
Page 126: ...Optional Equipment Installation 114 025 9416...
Page 134: ...Voice Prompts 122 025 9416...
Page 174: ...Parts Lists and Schematics 162 025 9416 Schematic...
Page 175: ...Parts Lists and Schematics 025 9416 163...
Page 176: ...Parts Lists and Schematics 164 025 9416...
Page 177: ...Parts Lists and Schematics 025 9416 165...
Page 178: ...Parts Lists and Schematics 166 025 9416...
Page 179: ...Parts Lists and Schematics 025 9416 167...
Page 180: ...Parts Lists and Schematics 168 025 9416...
Page 181: ...Parts Lists and Schematics 025 9416 169...
Page 182: ...Parts Lists and Schematics 170 025 9416 Silkscreen...
Page 185: ...Parts Lists and Schematics 025 9416 173 Schematic...
Page 186: ...Parts Lists and Schematics 174 025 9416...
Page 187: ...Parts Lists and Schematics 025 9416 175...
Page 188: ...Parts Lists and Schematics 176 025 9416...
Page 189: ...Parts Lists and Schematics 025 9416 177...
Page 190: ...Parts Lists and Schematics 178 025 9416 Silkscreen...
Page 193: ...Parts Lists and Schematics 025 9416 181 Schematic...
Page 194: ...Parts Lists and Schematics 182 025 9416...
Page 195: ...Parts Lists and Schematics 025 9416 183...
Page 196: ...Parts Lists and Schematics 184 025 9416 Silkscreen...
Page 198: ...Parts Lists and Schematics 186 025 9416 RAM Disk 702 9386B ROM Disk 702 9389B...
Page 199: ...Parts Lists and Schematics 025 9416 187 TNPP Interface 702 9362C 2...
Page 200: ...Parts Lists and Schematics 188 025 9416 Terminal Block Adapter 702 9470B...
Page 201: ...Parts Lists and Schematics 025 9416 189 CONFIGURATION DIAGRAMS Dual Trunk Telco DID 024 0076A...
Page 202: ...Parts Lists and Schematics 190 025 9416 Dual Trunk Telco End to End 024 0077A...
Page 203: ...Parts Lists and Schematics 025 9416 191 Dual Trunk Telco E M 024 0078A...
Page 204: ...Parts Lists and Schematics 192 025 9416 Dual Trunk Telco Ground Start 024 0079A...
Page 210: ...025 9416...