Section 4. Programming
4-13
PL Strip Output
The auxiliary output FET can be configured for use as a PL strip output. If
enabled, the FET pulls the output to ground during paging, and remains there for
the duration of a page initiated call. This is intended to indicate to the radio that
subaudible signaling should be turned off.
87#
___#
Use Auxiliary Output for PL Strip
(0 = Disabled, 1 = Enabled)
0
Auxiliary Output Control
The Model 30 provides an open drain FET circuit as an auxiliary output. This
can be used to control external equipment that is located at the radio site. When
the Auxiliary Output is turned ON, the FET pulls the output to ground and holds
it there until the OFF command is received. These commands allow the system
operator to program new access codes for ON and OFF.
88#
___#
Set Auxiliary Output ON Code (1 to 9 digits)
567
89#
___#
Set Auxiliary Output OFF Code (1 to 9 digits)
890
Program Access Code
This command allows the system operator to program a new access code in the
field to maintain system security. The Program Mode Access Code must always
be five digits long. The default code is “
12030”.
90#
______#
Set Program Access Code (Must be 5 digits)
Reset All Parameters to Factory Default
This command is used quickly return all programmable parameters in the Model
30 to known, factory default values. All programming changes must be re-
entered after using this command.
91#
Reset All Memory to Factory Defaults
Summary of Contents for 30 Worldpatch
Page 2: ......
Page 6: ...Table of Contents Continued ...
Page 49: ...Section 6 Repair 6 5 Schematic ...
Page 50: ...Section 6 Repair 6 6 ...
Page 51: ...Section 6 Repair 6 7 ...
Page 52: ...Section 6 Repair 6 8 Silkscreen ...
Page 60: ...Section 7 Programming Log And Quick Reference 7 8 ...