Appendix A: Details of Model 6203/6204 Hardware
160
Jumper Details
There are 15 selectable jumpers on the Model 6203 Transponder circuit board and four on
the Model 6203 Power Supply circuit board. The position of these jumpers affects the
performance of the Model 6203.
Transponder Board Jumpers
The Transponder circuit board is located on the hinged cover of the Model 6203 case.
Please see
for the relative locations of the jumpers on this board.
The following table provides a quick reference of each jumper on the transponder board.
The default setting for each jumper is in bold face type.
Table 9: Transponder Board Jumpers
1
A special “summing” jumper is used on JP14, except in cases where the M6203 or M6204 is used
in a Model 26-based system to replace a Model 6. In that situation, use a regular jumper on
A
or
B
as
appropriate.
Jumper
Description
Position A
Position B
No Jumper
JP1
Ram Select
32K
8K
8K
JP2
JP2 is for testing purposes only and should otherwise never be installed
JP3
VOX Control
VOX Disabled
VOX enabled
VOX enabled
JP4
FFSK RCV
Select
Bypass AGC
Enables AGC
Prevents reception of all data
from Model 26
—
—
TEL
PWR
RAD
No Jumper
JP5
FFSK Output
Range
Middle Output
Level
Highest Output
Level
Lowest Out-
put Level
Same as TEL
(Middle Output)
JP6
The posts for jumper JP6 are not normally installed
JP7
The posts for jumper JP7 are not normally installed
JP8
This jumper is no longer used. Leave it set to the default position.
JP9
COR Input
Pull-Up
Pulled-up
(default)
Floating
Floating
JP10
4-Wire RCV
Impedance
600
Ω
10 k
Ω
10 k
Ω
JP11
Baud Rate for J6
9600
4800
2400
JP12
J6 Serial Data
Received On
A
(Pin 2)
B
(Pin 4)
No Jumper
JP13
J1 Serial Data
Received On
A
(Pin 2)
B
(Pin 4)
No Jumper
JP14
Source of Audio
to PA
(2)
PA audio from
normal Rx pair
PA audio from
AUX input on J4
No audio
JP15
Auxiliary Audio
RCV Impedance
600
Ω
10 k
Ω
10 k
Ω
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...