SET-UP AND TEST 
 
The board is preset to give an output |Voltage of 1.5V for a load current of 1.5A (SL1 is shorted to connect in 
the 100m

 (R1) sense resistor).  To change the board to give an output Voltage of 1.5V for a current of 6.0A, 

de-solder SL1 and short SL2. This connects the 25m

 (R2) sense resistor. 

 
1.0 Ampere load test     (forward current flow) 
 
1.  Ensure SL1 is shorted.  
2.  Connect a linear power supply of +15V between the V1 and GND terminals. 
3.  Set a load current of 1.5A between the V2 and GND terminals using a suitable load.  

The load must be rated for at least 30W.  

4.  Check with a DVM the supply voltage is +15V between the V1 and GND terminals.    
5.  Measure VOUT with a DVM. The nominal output voltage should read 1.5V.  
6.  Measure the FLAG pin with a DVM, it should be High, approximately V1 15Vin this case. 
 
 
1.0 Ampere load test     (reverse current flow) 
 
1.     Ensure SL1 is shorted.  
2.  Connect a linear power supply of +15V between the V2  and GND terminals. 
3.  Set a load current of 1.5A between the V1 and GND terminals using a suitable load.  

The load must be rated for at least 30W

4.  Check with a DVM the supply voltage is +15V between the V2 and GND terminals.    
5.  Measure VOUT with a DVM. The nominal output voltage should read 1.5V.  
7.    Measure the FLAG pin with a DVM, it should be logic Low,  less than 200mV 
 
 
 
The device may also be evaluated with lower power loads and lower currents by increasing the value of 
R

sense. 

  As the device  reacts only to the voltage across this resistor such tests are equally valid. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ZXCT1041 EV1

Page 1: ...s set up to provide an out put of 1 5V from a current of 1 5A using a 100 m sampling resistor There is a second 25 m resistor that can be selected by means of a solder link and provides an output of 1...

Page 2: ...ction of current flow GND 0V Ground SL1 SL2 Solder Links Vcc Not used Figure 1 ZXLD1350EV2 evaluation board The ZXCT1041EV1 is configured as shown in figure 1 SL1 is shorted to output 1 5V for a 1 5A...

Page 3: ...s are shorted the effective resistance is20m giving an output of 1 5V for a current of 7 5A assuming that R3 is not fitted If both links are open only the optional leaded resistor R3 if fitted is in c...

Page 4: ...en output current The value of Vout is 10 times the voltage dropped across the sensing resistor providing that the input Voltage is more than 2 7V higher than the Vout Choosing a larger value for Rsen...

Page 5: ...etween the V1 and GND terminals 5 Measure VOUT with a DVM The nominal output voltage should read 1 5V 6 Measure the FLAG pin with a DVM it should be High approximately V1 15Vin this case 1 0 Ampere lo...

Page 6: ...ONNECTION DIAGRAM Forward Current flow PSU DVM GND V1 V2 VOUT GND LOAD ZXCT1041EV1 FLAG 10 DVM CURRENT MONITOR EVALUATION BOARD CONNECTION DIAGRAM continued Reverse Current flow PSU DVM GND V1 V2 VOUT...

Page 7: ...User Guide Rev2 EVALUATION BOARD CURRENT MONITOR EVALUATION BOARD Vcc GND GND Vout FLAG SL1 SL2 R1 R2 SL3 ZXCT R3 V1 V2 R5 Refer to User Guide for details Bare board ZDB341R2 Copyright Zetex PLC 2006...

Page 8: ...uality of service and products we strongly advise the purchase of parts directly from Zetex Semiconductors or one of our regionally authorized distributors For a complete listing of authorized distrib...

Reviews: