background image

LED Power Indicator Light: 

The LED indicator can be used to determine current power remaining. Blue 

LED indicates a charge of 100% to 50%, red LED indicates 50% to 25% and a blinking red LED light means 
less than 25% remaining. At 10% the Relic BB will turn off completely due to the automatic activation of 
over-discharge protection. 

 

Recharging your Relic BB: 

You can recharge your 18650 batteries through the Micro-USB port using the 

supplied Micro-USB power cable. We recommend using a standard 5V 1A USB AC adapter, similar to the 
kind that is used to charge your mobile phones. Note: You cannot recharge RCR123 or standard CR123 
batteries using this method. 

You must press on the tail-cap switch to activate recharging.

 

 

CLEANING AND MAINTENANCE 

We recommend that you clean your ZeroHour Relic BB regularly. 

Wipe the threads and O-rings with a clean, lint-free cloth, and apply a thin coat of non-conduction 
silicone or petroleum-based lubrication. When the O-rings show signs of damage or are worn out from 
normal wear and tear, replace them and give ZeroHour Relic BB a new coat of lubrication. 

Clean the internal components such as the battery contact springs with isopropyl alcohol on cotton 
swabs. 

The body can be cleaned with soap and water. Remove the battery, tailcap switch, and the USB head 
before you clean the body tube. Use a cotton or microfiber towel to dry it off. 

Take care when cleaning to avoid any kind of moisture on the electronic terminals (e.g. USB ports and 
charge port). 

 