Zero88 SWITCH 6 User Manual Download Page 3

SWITCH 6 USER GUIDE   

 

 

Zero88 Lighting Ltd, Usk House, Llantarnam Park, Cwmbran, Gwent NP44 3HD, U.K 

Tel: +44 (0) 1633 838088 (24hr Answer Phone) Fax: +44 (0) 1633 867880 

73-877-00                                                       Email: 

[email protected]

 

IM7804Switch6ManualIssue1_3.doc 

www.zero88.com

 

Page 3 of 4 

Chillinet: 
 
Remote  control  of  the  Switch  6  is  possible  using  the 
Chillinet connectors mounted on the front panel. Each unit 
on a Chillinet system must have a unique unit number. 
 
To  enable  Chillinet  and  set  the  unit  number,  Select 

‘Chillinet’

 using the ‘Mode’ button. 

 
Set  the  unit  number  using  the  ‘Up  &  Down’  Arrows  and 
press  ‘Enter’,  to  confirm.  The  display  will  flash  the  unit 
number  while  it  is  checked  against  other  units  on  the 
network. 
 
If the  unit  number  is  found to  be unique,  then  the  display 
will return to being steady. If the unit number already exists 
on the network, the display will show   ‘---‘. 
 
‘---‘ indicates that Chillinet is disabled. To disable Chillinet, 
hold down the ‘Up & Down’ Arrows together. 
 
Memory  selection  from  Chillinet  is  only  possible  when  a 
DMX control signal is not present. 
 
The Chillinet network incorporates an ‘Alarm’ feature. If an 
Alarm  message  is  received  from  another  unit  on  the 
network, then the Switch 6 will fade all outputs to 80%, and 
the  display  will  show  ‘ALA’.  In  this  state,  all  other  control 
(INCLUDING  OVER  TEMPERATURE  SHUTDOWN)  is 
disabled. 
 
Note that the Switch 6 calculates fades internally, with the 
output transition occurring at a fixed level of 50%. 
 
 

Super User: 

 
The unit has a number of hidden functions, located in the 
Super  User  Menu.    The  super  user  menu’s  can  only  be 
accessed from the 

Default 

mode (No LEDS Lit).  To enter 

Super  User  press  and  hold  the  ‘Up  &  Down’  Arrows 
together  and  press  and  hold  the  ‘Mode’  button  for  5 
seconds.  All the mode LED’s will flash to indicate the unit 
is in super user mode. 
 
The  ‘Up  &  Down’  Arrows  are  used  to  cycle  through  the 
various super user functions. Pressing the ‘Mode’ button at 
any point will revert to normal operation.  If no buttons are 
pressed after 20 seconds the unit will automatically revert 
to normal operation. 
 
Unit Lock/Unlock  
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“LOC”. 

Press  ‘Enter’  to  confirm  this  action.    The  unit  will 

revert to the Default mode. Pressing the ‘Mode’ button now 
will  only  cycle  between 

Manual  Control

  and 

Default 

Mode. 
 
If Super User is entered when the unit is locked, only the 
unlock  function  will  be  available.    The  display  will  show 

“UNL”.

  To  unlock  the  unit,  press  and  hold  the  ‘Enter’ 

button  for  5 seconds.   The  unit  will  unlock  and  exit  super 
user returning to the Default mode. 
 
DMX Termination: 
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“ter”

.    If  the  unit  is  terminated  a  dot  will  appear  at  the 

bottom of the last segment.  Pressing the ‘Enter’ button will 
toggle between the two states. 
 

Resetting The Unit:  
 
Press  the  ‘Up  &  Down’  Arrows  until  the  display  shows 

“rst”

.  Press ‘Enter’ to confirm. The display will flash briefly 

to  confirm  this  action.   The  unit will  be  reset to  its  default 
settings, shown in the table below: 
 

Set Up Parameter 

State  

Manual Control Levels 

All Off 

DMX Address 

DMX Fail Mode 

Hold Last State 

Memory 

Memory Cleared 

Chillinet 

Disabled 

DMX termination 

Disabled 

 
Firmware Version: 
 
To identify which version of firmware is loaded in the unit, 
press the ‘Up & Down’ Arrows until the firmware version is 
shown in the display 

(e.g. 1.03)

 The ‘Enter’ button has no 

use here.  (The firmware version will also be shown briefly 
on start up). 
 
Internal Temperature:   
 
Press  the  ‘Up  &  Down’  Arrows  until  the  temperature  is 
shown  in  the  display,  shown  as 

xxC

,  where  xx  is  the 

temperature  in  Centigrade.    The  ‘Enter’  button  has  no 
function in this mode. 
 
Servicing Functions: 
 
Versions of firmware prior to 1.03 include other functions 
within Super User, which are used for servicing and 
maintenance purposes.  It is strongly recommended that 
these are only accessed by Zero 88 staff or an appointed 
Zero 88 dealer.  From firmware version 1.03 onwards, 
these functions are hidden in normal operation. 