![Zero Zone RVZC30 Installation & Operation Manual Download Page 46](http://html1.mh-extra.com/html/zero-zone/rvzc30/rvzc30_installation-and-operation-manual_3474979046.webp)
DEFROSTING
LOW TEMP (CONT.)
DEFROST HEATER ELEMENT
On 30" door cases, one half of the U-shape heater is located on the front of the coil and the other half is located on the rear of the coil
(
). On 24" door cases and wrap-around cases, the heater element is located under the coil (
). The electric wire leads are connected in the junction box behind the front kick rail.
HEATER ELEMENT REMOVAL
Front and rear heater location (VZ and VZT2 30" door)
The U-shape defrost heater has one leg located on the front of the coil and one leg located on the rear of the coil. The front heater is
located approximately 1" off the floor and the rear heater is approximately 2" off the floor. The heater is secured to the coil by a number
of stainless steel heater retaining clips. The heater is fastened to the floor on the right-hand side of the coil. Remove fasteners holding the
heater to the floor.
The U-shape defrost heater can be removed by first pulling the front leg of the retaining clip away from the coil and sliding the heater out
from under the clip. The rear leg of the heater can then be removed by raising the retaining clips 2 inches at a time, working from right to
left on the coil. Repeat this process until the retaining clips are free of the coil. The heater will slide up with the retaining clip.
Under coil location (MZ 24" and WA door).
To remove the defrost element, remove the coil covers. Lift the inner coil cover upward and tip the fan housing forward. This will expose
the coil. Remove both fan housing end brackets and center coil supports, then slide out the complete heater pan assembly from under
the coil. Slowly lift the heater pan assembly between the coil and fan housing, turning it on edge while lifting.
Heaters are installed in the reverse order of how they were removed.
42 • Defrosting - Low Temp
Summary of Contents for RVZC30
Page 2: ......
Page 4: ......
Page 36: ...ELECTRICAL LOW TEMP Figure 26 Electric Defrost 30 24 Wiring 32 Electrical Low Temp...
Page 37: ...ELECTRICAL LOW TEMP CONT Figure 27 Hot Gas Wiring Electrical Low Temp 33...
Page 38: ...ELECTRICAL LOW TEMP CONT Figure 28 Single Point Wiring 34 Electrical Low Temp...
Page 39: ...ELECTRICAL LOW TEMP CONT Figure 29 Master Satellite Wiring Electrical Low Temp 35...
Page 40: ...ELECTRICAL MEDIUM TEMP Figure 30 RVCC30 and RMCC24 Wiring Diagram 36 Electrical Medium Temp...
Page 41: ...ELECTRICAL MEDIUM TEMP CONT Figure 31 Single Point Wiring Electrical Medium Temp 37...
Page 42: ...ELECTRICAL MEDIUM TEMP CONT Figure 32 Master Satellite Wiring 38 Electrical Medium Temp...