background image

2

Author: Rudi          Version: 2.1          Revision: 1.2          Revision Date: June 2019

TECHNICAL DATA

Zero Appliances Model GF230IP

Freezer

Category:

I

3+ (28-30/37)

For use on Butane at 2.8-3.0 kPa
and Propane at 3.7 kPa.

I

3 B/P (30)

For use on Butane and Propane
mixtures (LPG) at 3.0 kPa

Declared rate:

Injector size 0.42mm diameter, marked ‘13’ or 0

Gas consumption:

34.2 g/h

Electrical Supply:

230V (Mains Electricity) 0.360kW

This appliance is a single lid single bin chest type freezer and has
a hanging storage basket.

WARNING: THIS APPLIANCE MUST BE

EARTHED

ENSURE THAT THE GAS SUPPLY HOSE IS

NOT IN CONTACT WITH OR NEAR THE

BURNER BOX

Manufactured in South Africa by:

Zero Appliances (Pty) Ltd.
P.O. Box 426
Edenvale 1610

Gauteng Province

INSTALLATION INSTRUCTIONS:

Summary of Contents for GF230IP

Page 1: ...OR THE ZERO MODEL GF230IP SINGLE LID CHEST FREEZER 2 WAY L P Gas 230V Electric ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SUPPLY HOSE I...

Page 2: ...ed rate Injector size 0 42mm diameter marked 13 or 0 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 360kW This appliance is a single lid single bin chest type freezer and has a ha...

Page 3: ...on of South Africa may install a gas installation The installation must be installed in accordance with the requirements of SANS 10087 1 and any fire department regulations and or local bylaws applica...

Page 4: ...etc the gas pipes may contain some air which should be allowed to escape by briefly pressing on the safety valve knob A This will ensure that the flame lights quickly Do not press knob A for more than...

Page 5: ...er or gas supplier immediately Do not store or use gasoline or other flammable vapour and liquid in the vicinity of this or any other appliance USER OPERATING INSTRUCTIONS TO START ELECTRIC OPERATION...

Page 6: ...baffle 2 Loosen the retainer screws B2 on the element and slide the element out of bottom the chimney A1 3 Insert the burner C1 onto the bottom of the chimney A1 4 Fasten the retainer screws C2 to the...

Page 7: ...ce is connected to the same supply check if it works properly 5 If the appliance fails to work on 230V Mains Electricity check a That the 230V supply is connected to the unit b That there are no loose...

Page 8: ...ning after releasing the fail safe valve knob according to the instructions there may be two faults these being a The magnet in the flame failure device 3 is faulty b The thermocouple feeler point 6 m...

Page 9: ...and a tablespoon of bicarbonate of soda Soak a soft cloth in the solution wring it out and use it to clean out the interior of the freezer compartment and its fittings Do not use wax polish scouring p...

Page 10: ...OUTINE MAINTENANCE It is recommended that a suitably qualified person service this appliance at least once a year Inspect the gas hose for cracks and chafing marks Test all connections with a suitable...

Page 11: ...isted under Troubleshooting In the unlikely event of cooling unit failure contact the national distributor without delay IMPORTANT NOTE If there is a smell of ammonia it is advised that the user turn...