D2O RG1 Product Manual - 19
COMMAND SYNTAX
DETAILS
time -g
Displays the verbose system time in GMT
Time Parameters
COMMAND SYNTAX
DETAILS
gps -g
Displays the last acquired GPS position as Latitude and Longitude with GMT time acquired
gps -v
Displays if the GPS Fix is Valid
Global Positions System (GPS) Parameters
COMMAND SYNTAX
DETAILS
acq -t
<hh>
Sets the Acquisition Synchronisation Time: Hour of Day (0 - 23) GMT.
Admin Restricted
Data Acquisition and Configuration Parameters
COMMAND SYNTAX
DETAILS
msg -g
Displays the date and time (GMT) of the next satellite transmission opportunity
Satellite Network Parameters
COMMAND SYNTAX
DETAILS
inp -c
<0.1 to 5.0>
Sets the Rain Gauge Bucket volume in millimetres (0.1mm precision) in the range of 0.1mm
to 5.0mm.
Admin Restricted
inp -g
Displays the total rainfall that has been recorded in millimetres since deployment
inp -z
<confirm>
Resets the pulse counter to zero. Enter
CLEAR
at
<confirm>
to avoid accidental use.
Admin Restricted
Rain Gauge Input Parameters
COMMAND SYNTAX
DETAILS
sys -c
Displays the Network Module Registration Code
sys -d
Displays the Receiver’s background noise level or RSSI (Received Signal Strength Indicator)
in dBm
sys -q
Displays the remaining storage space in the transmission queue in bytes
sys -L
Displays an estimate of the remaining power in the battery as a percentage (0% to 100%)
sys -p
<ON or OFF>
Sets the Battery’s Power Switch State to either
ON
or
OFF
. Setting to
OFF
is an
Admin
Restricted
command
sys -P
<password> <password>
Sets a new administrator password. The new password parameter must be entered twice,
separated by a space. Passwords must not contain whitespace. This is an
Admin Restricted
command
sys SC
<1000 to 50000> <pw>
Resets the battery capacity after replacement. Requires battery pack capacity to be entered
as well as a special password provided by Zepiro. Please contact your dealer for assistance
D2O Unit System Parameters