background image

9

&(1 0(/

:

Duct pieces

Total

Equivalent number
length x used      =

3-1/ 4” x 10”
Rect.,
straight

1 Ft.           x (     ) =

Ft.

7”-10” Round,

straight

1 Ft.           x (     ) =

Ft.

3-1/ 4” x 10”
Rect.90

0

elbow

15 Ft.         x (     ) =

Ft.

3-1/ 4” x 10”
Rect.45

0

elbow

9 Ft.           x (     ) =

Ft.

3-1/ 4” x 10”
Rect.90

0

flat elbow

24 Ft.         x (     ) =

Ft.

3-1/ 4” x 10”
Rect.
wall cap
with damper

30 Ft.         x (     ) =

Ft.

3-1/ 4” x 10”
Rect.to
6” round
transition

5 Ft.           x (     ) =

Ft.

3-1/ 4” x 10”
Rect.to
6” round
transition
90

0

elbow

20 Ft.         x (     ) =

Ft.

6” Round,
90

0

elbow

15 Ft.         x (     ) =

Ft.

6” Round,
45

0

elbow

9 Ft.           x (     ) =

Ft.

Ft.

6” Round,
straight

1 Ft.           x (     ) =

Ft.

Subtotal column 1 =

Duct pieces

Total

Equivalent number
length x used      =

6” Round
wall cap
with damper

30 Ft.         x (     ) =

Ft.

Round

wall cap
with damper

30 Ft.         x (     ) =

Ft.

7” - 10” 

Round,

90

0

elbow

15 Ft.         x (     ) =

Ft.

7” - 10” 

7” - 10” 

Round,

45

0

elbow

9 Ft.           x (     ) =

Ft.

Ft.

Ft.

Ft.

6” Round,
roof cap

30 Ft.         x (     ) =

Ft.

7” - 10”

Round,

roof cap

30 Ft.         x (     ) =

Ft.

Subtotal column 2 =

Subtotal column 1 =

Total ductwork      =

6” round to
3-1/ 4” x 10”
rect.
transition

1 Ft.           x (     ) =

Ft.

6” round to
3-1/ 4” x 10”
rect.
transition
90

0

elbow

16 Ft.         x (     ) =

Ft.

7” round to
3 1/ 4” x 10”
rect.
transition

8 Ft.           x (     ) =

Ft.

7” round to
3-1/ 4” x 10”
rect.
transition
90

0

elbow

23 Ft.         x (     ) =

Ft.