background image

www.zephyronline.com

10

In

s

ta

lla

ti

o

n

-

P

re

p

a

rin

g

H

o

o

d

fo

r

E

xt

e

rn

a

l

B

lo

we

r

The external blower kit consists of an 8”
collar, external flange and external blower
wiring box. The external blower is purchased
separately.

ATTENTION

The following are instructions on preparing your hood for installation with external blower model CBE-1000.
For instructions on installing internal blower model CBI-600 please turn to page “8”.

1. P osition and attach external blower wiring
box and junction box using provided 1/2” self
tapping screws and 4mm internal diameter
washers.

2. Attach grounding wires from external
blower wiring box and junction box to
grounding screw as shown in Fig-A.

3. Position and attach external flange to
motor housing using provided 1/2” self
tapping screws.

4. Attach junction box and external blower
wiring box connectors to control board and
wiring box connectors inside hood.

Continue to page “11” for hood
installation instructions.

Summary of Contents for Trapeze CTP-E 48SX

Page 1: ...Trapeze CTP E 48SX CTP E54SX CTP E 60SX Model number Serial number Use Care and Installation Guide MAY07 0101 Zephyr Corporation www zephyronline com Date of Purchase Sales Dealer...

Page 2: ...www zephyronline com...

Page 3: ...ion Sheet Mounting Height and Clearance Ducting Specifications Internal Blower Preparing Hood for External Blower Mounting the Hood FEATURES CONTROLS Controls Overview MAINTENANCE Cleaning Lights TROU...

Page 4: ...DO NOT USE WATE R includingwet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate...

Page 5: ...s 4 Adhesive Fasteners 4 Cable Ties 1 SMALL HARDWARE PACKET 10 Short Set Screws 12 MediumSet Screws 1 Tool 1 1 External Flange with Attached 8 Collar 1 Junction Box with Wires 1 External Blower Wiring...

Page 6: ...straight 1 Ft x Ft Subtotal column 1 Duct pieces Total Equivalent number length x used 6 Round wall cap with damper 30 Ft x Ft 7 Round wall cap with damper 30 Ft x Ft 7 Round 900 elbow 15 Ft x Ft 7 Ro...

Page 7: ...tal duct work ALWAYS when possible reduce the number or transitions and turns If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from openingas possi...

Page 8: ...attics or garages All exhaust must be ducted to the outside Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duc...

Page 9: ...9 6 9 2 5 x a M 4 3 n i M 26 5 8 32 48 54 59 1 8 Min 21 Max 40 12 1 8 7 n o i t a l l a t s n I s n o i t a c i f i c e p S 2 2 7 64 13 32 32 9 6 1 7 0 1 2 1 9 9 8 1 4 R 2 3 5 1 8 3 1 4 6 1 2 0 1 O 10...

Page 10: ...nstructions on preparing for external blower model CBE 1000 please turn to page 10 Before installing verify that motor spins freely 1 Remove existing screws from blower housing 2 Attach capacitor box...

Page 11: ...as shown 8 Place blower with attached flange into motor housing as shown on Fig A 9 Attach using 1 2 self tapping screws to secure in place 10 Att ach other end of capacitor box connector and junction...

Page 12: ...ternal blower model CBI 600 please turn to page 8 1 P osition and attach external blower wiring box and junction box using provided 1 2 self tapping screws and 4mm internal diameter washers 2 Attach g...

Page 13: ...wood blockings minimum 2x4 studs to ceiling joists 4 Center mark and fasten ceiling mounting plate onto ceiling where hood is to be hung Make sure the tabs on the ceiling bracket are positioned to th...

Page 14: ...ermine height of hood measure and select either 27 3 8 or 35 3 8 angle brac kets and attach 4 of them to the motor housing using 8 1 2 self tapping screws 2 for each angle bracket 3 Slide duct covers...

Page 15: ...will fit between the slots on the ceiling bracket One half of the angle bracket will be on the outside of the ceiling bracket and the other half will be on the inside of the ceiling bracket Attach usi...

Page 16: ...le 2 Attach a short set screw into each post in order to hold utensil rail onto canopy Do the same for the other side c a B t n o r F k Telescopic Rod Installation 1 Install telescopic rod thicker end...

Page 17: ...selected by presing to decrease and to increase speed level T he display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function...

Page 18: ...d with non abrasive soap or in a dishwasher Filter Clean Reminder When flashes on display the baffle filters installed are required to be cleaned This will occur after every 30 hours of use Re setting...

Page 19: ...ach Do not use orange cleaners Baffle Filters The Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are re...

Page 20: ...power is turned off and bulbs are not hot Remove bulb by pressing both ends of the metal retaining clip together the light socket will now extend from the hood allowing you to remove the bulb Be care...

Page 21: ...n of duct opening is against the wind 5 Using the wrong size of ducting 1 Baffle filter is loose 1 Control board needs to be reset 1 Defective control board 1 Make sure the circuit breaker and the uni...

Page 22: ...com Halogen Bulb GU 10 120V 50W Z0B 0020 Internal Blower 600 cfm CBI 600 External Blower 1000 cfm CBE 1000 Duct Cover Extension Kit Z1C 00TP List of Parts and Accessories Part Description Part Accesso...

Page 23: ...ices outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and...

Reviews: